image of an installed iSER Actuator
image of an installed iSER Actuator

Omnivise iSER™ Actuator - precisely control steam admission valve position

Omterra Omnivise Intelligent Self-Contained Electrohydraulic Redundant (iSER™) Actuators are designed to precisely control the position of steam admission valves for power generation turbines. iSER™ Actuators can be applied to any load, specifically for positioning, holding and trip applications. They meet the most stringent requirements for safety, reliability, and ruggedness.

 

Many steam turbines are controlled by antiquated mechanical hydraulic control (MHC) systems resulting in control issues, unplanned outages due to failures and wear, and high maintenance costs. In addition, the experienced personnel required to operate and maintain these systems are rapidly disappearing and finding replacement parts is increasingly difficult. The main barrier to upgrading to a modern electrohydraulic control (EHC) system is the exceptionally large capital investment in the demolition of the old system, installation of the new system, and updates to the plant control system. The single largest expense when modernizing a control system is typically the installation of new welded high-pressure piping for the hydraulic system.

The Omterra iSER™ Actuators solve these challenges at a significantly lower cost. Their self-contained design of these electrohydraulic actuators eliminates the main costs of piping installation while providing the precision control needed for operation and increasing the reliability, safety, and flexibility that turbine owners desire. In addition, Omterra iSER Actuators offer advantages over modern EHC systems, including eliminating virtually all leak points, greatly improved diagnostic capabilities, and enabling of predictive instead of reactive maintenance.

iSER actuator front and back view

Hydraulic cylinder

  • The hydraulic cylinder is specially designed for high pressures and special seals for preventing notable leakage.

Control manifold

  • Houses all of the pumps, valves, and sensors for operation. The only external fitting is for the makeup reservoir and filters, if used.

Trip manifold

  • Houses all solenoid valves and items needed for online valve stroke testing. 
  • Trip manifold can be configured to suit customers reliability and redundancy needs.

LVDT feedback

  • Equipped with rugged LVDTs designed to meet the demanding applications of the power generation industry. 
  • Simplex, duplex, or triplex configurations are available as well as integral LVDTs which mount inside the hydraulic cylinder.

Spring return

  • Spring is installed to operate as a fail-safe mechanism to close the steam valve in the event of an emergency. 
  • Custom configurations for fail-safe operation available.

Actuator specifications

  • Temperature range: -4 °F to 180°F (-20ºC to 82°C)
  • Fluid cleanliness ISO code: 18-16-13
  • Trip time: 200 ms (configuration dependent)
  • Standard seals are FKM/Viton

Hydraulic fluid

  • Must be non water-based
  • Must be non abrasive
  • Must be clean prior to filling
  • Must match desired operating temperature range

Power supply

  • Integral 24VDC power supply for PLC power and control functions

PLC

  • The PLC is the newest technology of Omterra PLC incorporating integrated I/O, compact design, and function block based programming.

HMI

  • Rugged outdoor HMI to display testing routines, configuration settings, diagnostic information, calibration mode and manual mode.

Emergency trip pushbutton

  • Local pushbutton trips actuator in event of an emergency.

Integral components

  • Circuit breakers and fuses for isolation and safety.

Control panel specifications

  • NEMA 4 (Other ratings available)
  • Temperature Range: 32-122°F (0-50°C)

Inputs

  • Power: 125 VDC 12A (AC versions available)
  • Trip input(s): 24 VDC, 120 VAC, or 125 VDC
  • Position demand signal: 4-20 mA
  • Profinet or ModbusTCP communications

Outputs

  • Actuator position: 4-20 mA
  • Actuator or motor temperature: 4-20 mA
  • Actuator open: Digital contact
  • Actuator closed: Digital contact
  • Actuator tripped: Digital contact
  • Alarm output: Digital contact
  • Warning output: Digital contact
  • Power supply fault: Digital contact
  • Profinet or ModbusTCP communications

Seal Options

  • Nitrile/Buna-N
  • Fluorocarbon/Viton

Rating Options

  • Various NEMA ratings available
  • SIL 3 (pending)
  • API 612 trip manifold

Actuator Temperature Options

  • Lower -30°F (-34°C)
  • Higher 212°F (100°C)
  • Special applications available upon request

Pushbutton Options

  • Local push buttons can be customized to customer needs.

Control Panel Options

  • Addition DI/DO/AO/Available
  • Redundant power supplies

Major U.S. utility selected iSER™ Actuators for two 650MW steam turbine units

 
  • Very complex existing control system
  • Loss of in-house system expertise
  • Maintenance cost of hydraulic system
  • High cost of actuator rebuild
 
  • Electrohydraulic actuator with modern compact design
  • Lower operational and rebuild cost
  • Improved steam turbine reliability
  • PLC controlled with common DCS interface
Image of an iSER actuator installation

Omnivise T3000 control system

Efficient power generation control goes beyond the precise adjustment of the steam admission valve position. Running a power plant or an entire fleet reliably and efficiently requires a trusted control core that evolves alongside your assets throughout their lifecycle.
Men is reading energy technologies news.

Newsletter

Sign up for the Omterra newsletter

Get the latest updates on technologies, expert insights, real-world projects shaping energy for society, plus invitations to upcoming events.
icon

Get in touch with us

For information and questions, our support team is available 24/7 to assist you in English, Spanish, and German.
Country/region
Job role
Is your inquiry related to installed equipment?
Industry (Select up to three)
Marketing consent