SF6-free switchgear operates without sulfur hexafluoride (SF6), the gas used in conventional gas-insulated switchgear and circuit breakers. Omterra, formerly Siemens Energy, builds its Blue portfolio on vacuum switching and clean air insulation instead: no fluorinated gases (F-gases), a global warming potential of zero, and products from 72.5 kV to 420 kV – gas-insulated switchgear (GIS), live-tank and dead-tank circuit breakers and gas-insulated busducts.
Decarbonizing the energy industry is about more than switching to renewable sources. To achieve zero Global Warming Potential (GWP) the transmission of power has to be as clean as its generation. This means eliminating F-gases from electrical switchgear – particularly SF6, a gas 24,300 times more climate-hostile than CO2.
Omterra’s Blue portfolio uses clean air and vacuum switching technology instead. Zero F-gases, zero toxicity and zero harm to human health and the environment.
Less global warming potential is not good enough, because 1% global warming potential is still global warming potential. It has to be zero and it has to be now.
Omterra has invested €60 million in its Berlin facility to step up production of vacuum interrupters for the Blue portfolio. This helps to secure the supply chain – and the plant runs on 100% renewable energy.
The 6,200 m² production area opened in 2024. The vacuum interrupter is the switching heart of every Blue product – sealed for life and maintenance-free.
Our Blue products use vacuum switching technology and clean air insulation to produce zero harmful emissions – and without having to compromise on performance or economic feasibility. With more than 15 years of experience in high-voltage vacuum switching, we have been able to maintain outstanding levels of technical performance and low lifecycle costs while removing F-gases from the switchgear entirely.
Blue is in operation in substations, wind turbines and offshore platforms today, and our strong partnerships with grid operators are taking it to higher voltages.
GWP = 0
Clean air consists of nitrogen and oxygen, natural origin gases. Global warming potential zero, no F-gas handling or reporting, no PFAS. That is the idea behind Blue: instead of replacing SF6 with another fluorinated gas, it removes F-gases from the switchgear altogether.
GWP ~ 500
A fluorinated gas mixed with CO2 and oxygen. The mixture’s global warming potential is several hundred (C4FN alone about 2,750), so it remains an F-gas under the EU bans, and C4FN falls under the PFAS restriction proposal that the European Chemicals Agency is assessing
GWP ~ 24,300
Global warming potential about 24,300. The established technology, but banned for most new high-voltage switchgear in the EU from 2028 and 2032.
Blue gas-insulated switchgear uses a vacuum circuit breaker and clean air insulation. The range covers the 8VM1 for wind turbine towers and the modular 8VM3 at 72.5 kV, the 8VN1 at 145 kV – the world’s first 145 kV GIS with vacuum and clean air – and the 8VQ3, the first gas-insulated busduct with clean air, for up to 420 kV. Low-power instrument transformers keep the bays compact – the answer to the larger gas compartments that clean air needs.
Blue circuit breakers combine vacuum interruption with clean air insulation and have the same footprint as their SF6 equivalents. The 3AV1 was the world’s first 145 kV live tank vacuum circuit breaker with clean air insulation, in operation at Netze BW since 2018, and is also available as dead tank breaker variant.
The 3AV2 live tank breaker takes the technology now to 420 kV and 63 kA.
Backed by EU funding and in partnership with Elia, operator of the electricity transmission network in Belgium, the LIFE Blue project is well on the way to demonstrating for the first time the economic viability of a completely F-gas-free 420 kV GIS. Rigorous electrical endurance tests have recently taken place – and as Dr. Mark Kuschel was proud to announce here, these had a very successful outcome. Installation at Elia’s pilot facility in Brussels is due to take place shortly.
The EU has launched a multi-million euro project to reduce greenhouse gases across the entire energy chain – in particular, SF6 gas. Read how we’re working together with eleven other partners from nine countries to achieve eMISsion-free transmiSION switchgear for AC (SF₆-free 420 kV live tank circuit breaker) and DC (SF₆-free 550 kV DC gas-insulated switchgear).
Another EU LIFE-backed project, our Blue 245 kV live tank circuit breaker is currently being developed in partnership with Red Eléctrica, the sole transmission system operator for the Spanish electricity network.
Launched in April 2026, the four-year project aims to set the benchmark for clean air high-voltage power transmission.
Our new customizable 8VM3 switchgear operates at 72.5 kV and its modular design also gives it the flexibility to work in conventional onshore substations as well as offshore wind turbines.
At Omterra, we see a partnership as much more than a simple supplier-client relationship. It goes way beyond the placing and delivery of an order. Rather, it's a close alliance between both parties. We work together towards a shared goal, developing the end solution by exchanging ideas and expertise at every stage.
This collaborative, interactive approach is mutually beneficial. Solutions can be shaped to meet particular requirements and the optimal set-up is reached more quickly.
The Berlin factory is delivering 197 units of SF6-free 8VM1 Blue GIS for the Siemens Gamesa wind turbines of Hornsea 3, Ørsted’s 2.9 GW offshore wind farm in the North Sea. The 2,000th 8VM1 unit, delivered in April 2025, was part of this order. The wind farm is set to supply green energy to more than 3 million UK homes.
We delivered 160 bays of 8VM1 Blue GIS to the Hollandse Kust Zuid project off the coast of the Netherlands, which is capable of supplying up to three million Dutch households with green energy.
"Being CO2-neutral is the future and the target for our customers in the offshore wind market, as well as for us at Omterra." – Ann-Sofie Bonde Mortensen, Global Vertical Sales Manager Offshore Wind, Omterra.
Thanks to BKK Nett's use of Blue switchgear, the cruise ships in this Norwegian port now use only clean power - with zero greenhouse gas emissions, zero F-gases and zero pollution.
"We managed to make the change in Bergen despite having restricted space in our substations. The experience is what we expected: problem-free." – Jens Skar, Division Manager, BKK Nett.
The three 8VN1 145 kV bays at the Koengen substation, energized in 2020, were the world’s first SF6-free GIS with clean air and vacuum technology.
This high-voltage substation in Burladingen, southern Germany was the world’s first to combine SF6-free, eco-efficient switchgear with digitalization: five 8VN1 Blue GIS bays with low-power instrument transformers and Noedra Node sensors, in operation since 2022.
"The innovation level in this project is very high. The substation of the future is a bold step for us, that requires trust." – Marcel Engel, Netze BW expert for grid development.
When we supplied ten bays of our Blue switchgear to Fingrid, we were delivering the first GIS in the country that replaces F-gases with clean air.
"With Omterra we have found a reliable partner that offers innovative products with absolutely Zero climate-harming fluorinated gases." – Timo Kiiveri, Senior Vice President at Fingrid.
The digitally enabled 145 kV 3AV1 Blue circuit breakers installed at the Hesseln substation use the Noedra Node switchgear digitalization technology to enable more efficient and economic management and better-informed operational decisions.
"The medium-term replacement of the insulating gas SF6 is an essential component of the decarbonization strategy of our E.ON Group." – Dr. Markus Obergünner, Senior Vice President High Voltage Grid, Westnetz GmbH.
the Blue portfolio comprises different high-voltage products used in a substation using clean air as insulation medium instead of SF6.
air-insulated switchgear (AIS) and gas-insulated switchgear (GIS)
onshore and offshore substations up to 145 kV
vacuum interrupter is maintenance-free (sealed for life). Blue circuit breakers and GIS have a maintenance schedule of 12 years for visual inspection and checks; first mayor inspection after 25 years
Blue products contain no SF6 nor any other harmful F-gas or greenhouse gases.