Modernization & upgrades for industrial steam turbines
Modernization & upgrades for industrial steam turbines

Modernization & upgrades for industrial steam turbines

Modernizing industrial steam turbines is a strategic investment that enhances efficiency, reliability, and sustainability. Whether you are aiming to reduce steam consumption, extend equipment life, or adapt to changing operational demands, Omterra offers tailored upgrade solutions that deliver measurable results—backed by decades of OEM expertise.

SST Improved efficiency_illustrated gif

Reduce steam consumption and operational costs.

SST Adaptability_2_illustrated gif

Modify operating parameters to meet evolving process needs.

3 SST Minimized downtime_illustrated gif

Shorter shutdowns and fewer unexpected failures.

: SST Extended lifetime_illustrated gif

Avoid costly replacements and extend asset lifespan.

SST Profitability_illustrated gif

Boost output and reliability for long-term gains.

Enhance plant reliability with modern control solutions.

  • Technical and energy studies
  • Heat cycle optimization
  • Rotor dynamic analysis
  • T&T valve upgrades
  • Control system modernization
Steam turbine service, young woman inspecting the control cabinet
 Steam turbine service_5; men inspecting rotor amd blades
  • OEM-grade repairs and revamps
  • Remote diagnostics and digital monitoring
  • Long-term maintenance and parts plans
  • Footprint replacements and control upgrades
  • Regional service teams for fast response

Typical modernization scope of industrial steam turbines

Inlet pressures:

30–140 bar(a)

Steam temperatures:

400–550 °C

Power range:

2–300 MW (industrial segment)

A “footprint” turbine is a replacement turbine which does not require any significant modifications to be made to the existing base frame or foundation. The existing oil system, gearbox and driven machine (generator, compressor, etc.) can also continue to be used with no, or only minor modifications. If necessary, they can be adapted to the new operating parameters. The ideal solution when the current turbine is technically unmodifiable, the casing or steam admission components are at end-of-life or when continuous operation under design conditions is no longer possible.

While a turbine revamp only replaces the steam path to optimize performance while retaining the existing casing and structure.

In a nutshell: Footprint vs. Revamp

 

Footprint solution

Turbine revamp

Characterization

Drop-in replacement turbine with minimal modifications

Replace steam path while retaining casing and structure

When to use

Required modifications cannot be realized with existing casing or casing is at end -of-life / seriously damaged

Performance optimization needed with reusable casing

Installation time

Typically within standard major outage possible

Typically during standard major outage possible

Advantages

Lower initial cost

Higher performance ROI

Flexibility

More adaptable to new performance goals

Limited to existing layout

waste to energy plant Vienna, Austria
waste to energy plant Vienna, Austria

Download the paper

Complete the form to get your free copy of Industrial Steam Turbine Modernizations & Upgrades
Country/region
Job role
Industry (Select up to three)
Marketing consent

TURLOOP Portfolio: One Proven Core. Three Modern Platforms.

  • Best for: Standalone turbine operations and budget-conscious plant upgrades.
  • Architecture: Built on robust SIMATIC S7-400 hardware and ET200MP distributed periphery, using CFC (Continuous Function Charts) libraries and WinCC-HMI interfaces.
  • Best for: Chemical, petrochemical, and manufacturing facilities requiring harmonized process control based on PCS7 platform.
  • Architecture: Integrates turbine control logic directly into the broader PCS 7 Distributed Control System (DCS) through a unified CFC engineering environment.
  • Best for: Major conventional power plants, large-scale utilities, municipal power generation, district heating plants and waste-to-energy facilities.
  • Architecture: Integrates entirely within the Omnivise T3000 platform on a server architecture, delivering IEC 62443-certified cybersecurity and maximum data consistency.

Turloop™ Scalable Packages

Available in three scalable configurations to match your plant requirements:

  • Small – Essential control and protection
  • Medium – Extended monitoring and supervision
  • Large – Advanced automation and high availability

 

Beyond Turloop™

When plant standards require a specific automation platform, Omterra delivers tailored turbine control solutions using trusted third-party technologies, including Woodward 505.

Trade magazine articles

Men is reading energy technologies news.

Newsletter

Sign up for the Omterra newsletter

Get the latest updates on technologies, expert insights, real-world projects shaping energy for society, plus invitations to upcoming events.
icon

Get in touch with us

For information and questions, our support team is available 24/7 to assist you in English, Spanish, and German.
Country/region
Job role
Is your inquiry related to installed equipment?
Industry (Select up to three)
Marketing consent