OGT-600 gas turbine
OGT-600 gas turbine

OGT-600 gas turbine for high fuel flexibility and maximized uptime

Siemens Energy and Siemens Gamesa are now Omterra. The formerly licensed “SGT” product portfolio is now offered under its new name, “OGT.”

The Omterra OGT-600 (formerly called SGT-600) combines robustness with an excellent maintenance program for high availability and low operating cost.

With high reliability, excellent fuel flexibility, and third-generation DLE technology, the OGT-600 is a perfect choice for industrial power generation in combined heat and power (CHP) and combined circle power plants (CCPP), as well as onshore oil and gas power generation, and mechanical drives. It offers efficiency and cost-effectiveness. To date, more than 360 units have been sold, achieving 14 million operating hours and demontsrating a class-leading reliability rate of 99.5%.

OGT-600 industrial gas turbine

Dependable engine with excellent fuel flexibility
Simple cycle power generation

24.5 MW(e)

Mechanical drive

25.3 MW

Average fleet availability

96.2%

Average fleet reliability

99.8%

Units sold

363

Total operating hours

> 14M

This industrial gas turbine features a durable and dependable design, offers extensive fuel flexibility, and ensures reduced emissions.

The OGT-600 offers best-in-class fuel flexiblity that allows for high content of inert gases, hydrogen and heavy hydrocarbons:

  • Ethane 100%
  • Propane 100%
  • Butanes and heavy alkanes 15%
  • Hydrogen up to 75%
  • Nitrogen 40%
  • H₂S ≤ 3%

The OGT-600 features a third-generation dual-fuel Dry Low Emissions (DLE) combustion system:

  • NOₓ emissions level < 9 vppm
  • CO emissions level  < 9 vppm
  • Turn down 50% load
  • Same DLE system for dual and liquid operation
  • NOₓ emissions on liquid fuels < 63 ppmvd
  • CO emissions on liquid fuels < 10 ppmvd
  • Turn down 50% on liquid fuels
  • Dual-fuel DLE capability with fuel changeover capability (gas to liquid fuel and liquid fuel to gas) on load

The OGT-600 features a reliable, robust and easily maintainable design for maximized uptime.

  • Reliability > 99%
  • On-site or off-site maintenance
  • 24-hour swap capability
  • 14 maintenance days in 17 years
  • 34,000 equivalent operating hours (EOH) between hot section inspections
  • Part load operation increases the time between overhauls

Thanks to a long lifetime with maximized uptime, low life cycle cost and easy servicability, the OGT-600 offers a high lifetime profitability. The robust industrial design offers a low degradation over time.

The OGT-600 provides exceptional availability due to its robust and reliable engineering.

Ingenious design to the core

The OGT-600 offers the best-in-class availability thanks to a robust and reliable design.
The compact twin-shaft engine is easy to maintain and allows for flexible opeation.

Using the same design for power generation and mechanical drive increases the operational experience.

OGT-600 gas turbine compressor

Compressor

  • The OGT-600 core engine is equipped with a 10-stage flow transonic compressor.
  • It includes variable guide vanes to ensure robust operability.
  • The design is optimized to deliver high performance across a wide range of operating conditions.
ogt-600 power turbine

Free power turbine

  • The 2-stage uncooled free power turbine provides a nominal shaft speed of up to 7,700 rpm.
  • It can operate at 50 to 105% of the nominal speed for mechanical drive.
  • The blades feature interlocking shrouds to enhance robustness.

OGT-600 power generation and mechanical drive packages

Thanks to the compact architecture, the OGT-600 package offers a small footprint. The package has a modular and flexible design and features single-lift capability.
The driver for both power generation and mechanical drive package is the same.

A gas turbine package includes:
Gas turbine, enclosure, base frame, air intake, exhaust, lubricating systems, starter system, vibration monitoring system, firefighting system, package ventilation system, instrumentation, gas detection, fuel systems, gearbox (if needed).

OGT-600 power generation package

Power generation package

The OGT-600’s ability to handle sudden load changes and its high exhaust temperature make it ideal for simple cycle, combined cycle, cogeneration, and other heating applications.

  • Small footprint for easy fitting
  • Modular and flexible package design
  • Single-lift capability
OGT-600 mechanical drive package

Mechanical drive package

The OGT-600 mechanical drive packages offer long lifecycles and can withstand extreme climates ranging from desert heat to arctic cold, oil platforms, and harsh industrial environments.

  • Variable power turbine speed: 50 to 105%
  • High load on low-power turbine speed
  • Maintains efficiency at part load
  • Low emissions at part load

OGT-600-based power plants

For combined cycle and cogeneration (combined heat and power – CHP), we offer a broad range of power plant configurations and scopes based on the OGT-600 gas turbine. For combined cycle, 1x1 or 2x1 configurations are part of the standardized portfolio.

OGT-600 power plants

Excellent CC and CHP efficiency

Good combined cycle performance: In a 2x1 combined cycle configuration, the power output is 74.2 MW(e) at a net plant efficiency of 51.6%.

Comprehensive services to support you

The comprehensive Omterra service programs provides low life cycle cost and optimum performance throughout the turbine’s life cycle: overhaul service, field service, spare parts, service exchange, remote diagnostic service, and modernization and upgrades.

With only 14 scheduled maintenance days over a 17-year service cycle, the OGT-600 provides highest operational availability.  

Omterra specialists provide on-site or remote support worldwide for both scheduled and short-term needs. A global help desk offers 24/7 service access.

OGT-600 maintenance

Easy on-/off-site maintenance

  • The OGT-600 is designed to maximize serviceability.
  • It allows for on-site maintenance as well as gas generator removal for off-site maintenance.
  • Gas generator swap can be completed within 24 hours.
remote diagnostic static animation

Remote diagnostic service

  • The remote diagnostic service aids in early fault detection and outage prevention.
  • It encompasses online monitoring, expert performance data analysis, and fleet data comparisons.
ogt-600 gas turbine side view

Designed for easy serviceability

  • Burners are accessible from the outside for easy replacement.
  • Compressor casing is horizontally split, and the turbine casing is vertically split between gas generator and power turbine.
  • Multipe boroscope holes allow for internal visual inspection of the compressor.

High fuel flexibility

The OGT-600 offers best-in-class fuel flexibility that allows for high content of inert gases, hydrogen and heavy hydrocarbons:

  • Ethane 100%
  • Propane 100%
  • Butanes and heavy alkanes 15%
  • Hydrogen up to 60%
  • Nitrogen 40%
  • H₂S 3.5%

Features:

  • Available with both conventional and DLE combustion systems
  • Gaseous and liquid fuels on-load changeover
  • Third-generation DLE system
  • Best-in-class NOₓ emission levels

The OGT-600 requires low gas supply pressure at site: 24.5 bar(a) / 355.5 psi(a).

Low emission capability

The combustor and burner design give world-class emission performance over a wide load range and are capable of ≤ 9 ppmvd NOₓ emission levels.
Low emission levels are also received on liquid fuel without need of water injection.

Emissions for 100 – 50% load, NOₓ at 15% O₂:

  • Natural gas: ≤ 9 ppmv
  • Diesel No. 2: ≤ 63 – 38 ppmv

Emissions for 100 – 50% load, CO at 15% O₂:

  • Natural gas: ≤  9 – 80 ppmv
  • Diesel No. 2: ≤ 10 – 80 ppmv

(Emissions depend upon site conditions, required load range and other project-specific data.)

Performance data for simple cycle power generation

Gross power output24.5 MW(e)
Fuel¹Natural gas, dual fuel
Frequency50/60 Hz
Gross efficiency33.6%
Gross heat rate10,720 kJ/kWh (10,161 Btu/kWh)
Turbine speed 7,700 rpm
Pressure ratio14.0 : 1
Exhaust mass flow81.3 kg/s (179.2 lb/s)
Exhaust temperature543 °C (1,009 °F)
NOₓ emissions²≤ 9 ppmvd
All performance values are based on standard design, ISO ambient conditions and natural gas fuel. No intake or exhaust loss. | ¹1 Natural gas, other gases within specification, liquid fuel (Diesel No. 2) and dual fuel (gas and liquid) | ²NOₓ emissions at 15% O₂ on fuel gas (with DLE)

OCC-600: Performance data for combined cycle power generation

Combined cycle power plantOCC-600 1x1OCC-600 2x1
Gross power output36.5 MW(e)74.2 MW(e)
Gross plant efficiency50.7%51.6%
Gross heat rate7,105 kJ/kWh (6,734 Btu/kWh)6,981 kJ/kWh (6,616 Btu/kWh)
Number of gas turbines12
Note: All combined cycle performance is based on 2 pressure, no reheat.

OGT-600: Performance data for mechanical drive

Gross power output25.2 MW
Fuel¹Natural gas, liquid fuel, dual fuel
Gross efficiency34.6%
Gross heat rate10,390 kJ/kWh (9,848 Btu/kWh)
Turbine speed 3,850 – 8,085 rpm
Pressure ratio14.0 : 1
Exhaust mass flow81.3 kg/s (179.2 lb/s)
Exhaust temperature543 °C (1,009 °F)
NOₓ emissions²≤ 9 ppmvd
All performance values are based on standard design, ISO ambient conditions and natural gas fuel. No intake or exhaust loss. | ¹ Natural gas, other gases within specification, liquid fuel (Diesel No. 2) and dual fuel (gas and liquid) Change turbine speed to: 3,850-8,085 | ²NOₓ emissions at 15% O₂ on fuel gas (with DLE)

Physical dimensions and weight

Dimensions exclude inlet filter housing and exhaust stack. For power generation, the AC generator is included. For mechanical drive, the driven equipment is excluded.

 Power generation packageMechanical drive package
Approximate weight152,000 kg (335,000 lb)61,000 kg (135,000 lb)
Lenght18.8 m (61.7 ft)11.7 m (38.4 ft)
Width4.6 m (15.0 ft)4.0 m (13.1 ft)
Height4.0 m (13.1 ft)4.0 m (13.1 ft)

More than 360 units have been sold with over 14 million equivalent operating hours, and 180,000 equivalent operating hours for the fleet-leading gas turbine.

icon

Get in touch with us

For information and questions, our support team is available 24/7 to assist you in English, Spanish, and German.
Country/region
Job role
Is your inquiry related to installed equipment?
Industry (Select up to three)
Marketing consent