Distribution transformers are the last voltage step in the power grid. They convert the medium voltage of the distribution network down to the low voltage used by homes, buildings, industrial plants and renewable energy sites – typically from up to 36 kV on the primary side to 250–800 V on the secondary side – and they operate around the clock for decades. Their losses, reliability and footprint therefore shape both the operating cost and the resilience of every distribution network.
Omterra, formerly known as Siemens Energy, offers medium-voltage distribution transformers including GEAFOL cast-resin dry-type transformers and FITformer oil-immersed transformers. The range features CAREPOLE dry-type pole-mounted transformers alongside oil-immersed pole-mounted and pad-mounted solutions for overhead and underground distribution networks. With ratings from 25 kVA single-phase pole units up to 50 MVA dry-type and 100 MVA oil-immersed transformers, Omterra serves utilities, data centers, industry, infrastructure and green technologies, including wind and solar plants.
Distribution transformers differ first in how they are insulated and cooled – solid cast resin and air, or an insulating liquid – and second in where they are installed: indoors, in a substation, on a pole or on a concrete pad. Each design fits a different set of sites, ratings and safety requirements.
GEAFOL dry-type transformers insulate their windings with an epoxy resin and quartz powder mixture instead of oil. They are flame-retardant and self-extinguishing, meet fire behaviour class F1 under IEC 60076-11 and are specified wherever people, buildings and critical infrastructure are close to the transformer. The range covers ratings up to 50 MVA and voltages up to 52 kV.
FITformer oil-immersed transformers use mineral oil or biodegradable ester fluid for insulation and cooling. They are compact, highly efficient and largely maintenance-free, covering ratings up to 30 MVA and 145 kV. The portfolio serves utilities, data centers, industry, battery energy storage systems, and renewable energy projects, including wind and solar plants.
Pole-mounted transformers supply homes, farms, and small businesses directly from overhead distribution lines. Omterra offers CAREPOLE dry-type pole-mounted transformers with cast-resin insulation for ratings from 25 to 50 kVA and voltages up to 25 kV, alongside FITformer fluid-immersed pole-mounted transformers for utility distribution networks and rural electrification with ratings up to 500 kVA and voltages up to 36 kV.
Type | Omterra product | Rating | Voltage | Insulation | Typical sites |
Dry-type | GEAFOL, GEAFOL Neo | Up to 50 MVA (Neo up to 6.3 MVA) | Up to 52 kV Um (Neo 40.5 kV) | Cast resin, air (AN/AF) | Data centers, buildings, hospitals, metro, offshore, wind, industry |
Oil-immersed | FITformer | Up to 100 MVA | Up to 145 kV | Mineral oil or ester fluid | Utility grids, wind and solar plants, industry, data centers |
Pole-mounted | CAREPOLE (dry-type); FITformer (fluid-immersed) | CAREPOLE: 25-50 kVA single-phase; FITformer: up to 500 kVA | CAREPOLE: up to 25 kV; FITformer: up to 36 kV | Cast resin / mineral oil or ester fluid | Overhead distribution networks, utilities, rural electrification |
Pad-mounted | FITformer fluid-immersed pad-mounted | Up to 5.000 kVA | Up to 36 kV | Mineral oil or ester fluid | Underground distribution networks in North America |
Where fire safety and indoor installation decide, dry-type designs lead; where high ratings, outdoor installation and long-term overload reserves decide, oil-immersed designs do. Each type page explains the choice in detail.
Omterra distribution transformers operate at every point where medium voltage meets consumption or generation, from secondary substations and overhead lines to wind turbines and data centers.
Utilities install distribution transformers in secondary substations, on poles and on pads to supply homes and businesses. Low-loss designs reduce the losses that run through a network 24 hours a day, and oil-immersed units keep the supply within the permitted voltage band.
Steel mills, refineries, mining and conveyance facilities need transformers that withstand frequent drive peak loads and short circuits. FITformer and GEAFOL converter transformers combine high short-circuit withstand capability with high overload reserves for these duty cycles.
In wind turbines, Omterra transformers are installed in the substation, the tower or the nacelle; in solar parks they are built for outdoor installation with a touch-proof design. FITformer and GEAFOL units are tested for vibration, corrosion and temperature changes before they reach the site.
Data centers, hospitals, metro systems and high-rise buildings depend on transformers that deliver safe and reliable power. Omterra GEAFOL and FITformer solutions offer the flexibility to meet different infrastructure requirements, supporting reliable operation, scalability and efficient power distribution where continuity and performance are critical.
Distribution transformers are regulated for energy efficiency on both sides of the Atlantic. The EU Ecodesign regulation sets maximum load and no-load losses for transformers placed on the European market, and the US Department of Energy sets minimum efficiency levels for distribution transformers sold in the United States.
Omterra monitors the development of transformer regulations worldwide and designs every distribution transformer to the rules that apply where it is installed.
Omterra designs, manufactures and tests its distribution transformers in its own factories. Each factory has a high-voltage test bay for routine tests such as voltage, temperature-rise, insulation resistance, partial discharge and noise measurements, and short-circuit and vibration tests take place at internationally recognized institutes.
GEAFOL cast-resin technology was pioneered at our Kirchheim factory in 1966 and has been in reliable service ever since, evolving into a globally established and widely accepted transformer technology. Beyond distribution transformers, Omterra supplies voltage regulators, power transformers and transformer services, so utilities and industrial operators can source a transformer fleet and its lifecycle support from one manufacturer.
Omterra transformer services support distribution transformers across their service life, from commissioning and condition assessment to repair and retrofit [scope to confirm with the Transformer services page owner].
Operators reach the Omterra support team around the clock through the contact form below, in English, German and Spanish.
A distribution transformer is the last transformer in the power supply chain. It steps the medium voltage of the distribution grid down to the low voltage used by consumers – typically from up to 36 kV on the primary side to 250–800 V on the secondary side – while keeping the frequency unchanged.
Distribution transformers are grouped by insulation – dry-type (cast resin and air) or liquid-immersed (mineral oil or ester) – and by installation: indoor or substation units, pole-mounted units on overhead lines and pad-mounted units for underground networks. They are built as single-phase or three-phase units.
Power transformers work in transmission networks at high voltages and ratings of many MVA and run close to full load. Distribution transformers step medium voltage down to consumer voltage, carry loads that change over the day and are designed to keep no-load losses low.
Mostly, yes. Distribution transformers are medium-voltage transformers: their primary side is connected to the medium-voltage distribution grid, and their secondary side supplies low voltage to consumers.
Dry-type cast-resin transformers suit indoor sites and places close to people, where fire safety and no oil are decisive. Oil-immersed transformers suit outdoor sites, higher ratings and voltages, and applications with long overload periods. The dry-type page compares both designs in detail.