Siemens Energy and Siemens Gamesa are now Omterra. The formerly licensed “SST” portfolio is now offered as OIST (Omterra Industrial Steam Turbine) and OLST (Omterra Large Steam Turbine).
Whatever the requirements are, we provide either bare steam turbine drivers to OEMs, or we supply complete packages including gears, lube oil systems and controls.
The Dresser-Rand steam turbines include:
Its power output is 10kW up to 25 MW. The inlet steam pressure is 30 to 139 bar(a) and the inlet steam temperature is 415 to 550 °C.
We are a dedicated service provider for the legacy brands below including Dresser Rand, with regional service teams to support your local steam turbine maintenance needs. Our support includes OEM technical expertise for single stage, multistage and engineered multistage steam turbines. Our operations network features world-class factories, service centers, supplier network as well as warehouse logistics and inventory centers.
D-R RLH-15
D-R RLH-24
D-R B
D-R Tandem
| Power output | Turbine speed | Inlet steam temperature | Inlet steam pressure | Back-pressure | Condensing pressure | Bleedings / Extractions | |
|---|---|---|---|---|---|---|---|
| D-R RLA | 240 kW | ≤ 4,300 to 6,000 rpm | ≤ 440 °C | ≤ 47 bar(a) | ≤ 12 bar(a) | ||
| D-R RLVA | 240 kW | ≤ 4,300 to 6,000 rpm | ≤ 440 °C | ≤ 47 bar(a) | ≤ 12 bar(a) | ||
| D-R RLH-15 | 1,865 kW | ≤ 6,000 rpm | ≤ 482 °C | ≤ 63 bar(a) | ≤ 21 bar(a) | ||
| D-R RLH-24 | 1,865 kW | ≤ 6,000 rpm | ≤ 482 °C | ≤ 63 bar(a) | ≤ 21 bar(a) | ||
| D-R SST 350/500/700 | 3,500 kW | ≤ 12,000 rpm | ≤ 482 °C | ≤ 63 bar(a) | ≤ 202 bar(g) | ||
| D-R 2TA | 3,640 kW | ≤ 15,000 rpm | ≤ 530 °C | ≤ 101 bar(a) | ≤ 33 bar(a) | ||
| D-R AVTTW | 4,500 kW | ≤ 13,000 or ≤ 5,000 rpm | ≤ 550 °C | ≤ 125 bar(a) | ≤ 40 bar(a) | ||
| D-R GTW | 4,500 kW | ≤ 14,500 rpm | ≤ 550 °C | ≤ 125 bar(a) | ≤ 35 bar(a) | ||
| D-R C | 2,500 kW | ≤ 8,500 rpm | ≤ 520 °C | ≤ 120 bar(a) | 21 bar(a) | ||
| D-R GAF | 3,500 kW | ≤ 6,000 rpm | ≤ 440 °C | ≤ 49 bar(a) | ≤ 6 bar(a) | ≤ 0.05 bar(a) | |
| D-R U | 6,340 kW | ≤ 10,000 rpm | ≤ 455 °C | ≤ 46 bar(a) | ≤ 15 bar(a) | ≤ 0.05 bar(a) | |
| D-R R | 25,000 kW | ≤ 15,000 rpm | ≤ 482 °C | ≤ 63 bar(g) | ≤ 29 bar(g) | ≤ 0.05 bar(a) | 1 or multiple |
| D-R RS | 25,000 kW | ≤ 15,000 rpm | ≤ 482 °C | ≤ 63 bar(g) | ≤ 29 bar(g) | ≤ 0.05 bar(a) | 1 or multiple |
| D-R K | 4,850 kW | ≤ 10,000 rpm | ≤ 398 °C | ≤ 27.5 bar(a) | ≤ 5 bar(g) | ≤ 0.05 bar(a) | |
| D-R B | 11,000 kW | ≤ 9,500 rpm | ≤ 500 °C | ≤ 65 bar(a) | 6,9 bar(a) | Multiple | |
| D-R Tandem | 12,500 kW | ≤ 8,500 rpm | ≤ 530 °C | ≤ 111 bar(a) | ≤ 13 bar(a) | Multiple / 1 |
| Power output | Turbine speed | Inlet steam temperature | Inlet steam pressure | Back-pressure | Condensing pressure | Bleedings / Extractions | |
|---|---|---|---|---|---|---|---|
| D-R RLA | 321 HP | ≤ 4,300 to 6,000 rpm | ≤ 824 °F | ≤ 682 psi | ≤ 174 psi | ||
| D-R RLVA | 321 HP | ≤ 4,300 to 6,000 rpm | ≤ 824 °F | ≤ 682 psi | ≤ 174 psi | ||
| D-R RLH-15 | 2501 HP | ≤ 6,000 rpm | ≤ 900 °F | ≤ 914 psi | ≤ 300 psi | ||
| D-R RLH-24 | 2501 HP | ≤ 6,000 rpm | ≤ 900 °F | ≤ 914 psi | ≤ 300 psi | ||
| D-R SST 350/500/700 | 4,690 HP | ≤ 12,000 rpm | ≤ 900 °F | ≤ 914 psi | ≤ 315 psi(g) | ||
| D-R 2TA | 4,880 HP | ≤ 15,000 rpm | ≤ 986 °F | ≤ 1,515 psi | ≤ 480 psi | ||
| D-R AVTTW | 6,000 HP | ≤ 13,000 or ≤ 5,000 rpm | ≤ 1022 °F | ≤ 1,813 psi | ≤ 508 psi | ||
| D-R GTW | 6,000 HP | ≤ 14,500 rpm | ≤ 1022 °F | ≤ 1,813 psi | ≤ 508 psi | ||
| D-R C | 3,250 HP | ≤ 8,500 rpm | ≤ 986 °F | ≤ 1,740 psi | 315 psi | ||
| D-R GAF | 4,690 HP | ≤ 6,000 rpm | ≤ 825 °F | ≤ 715 psi | ≤ 87 psi | ≤ 0.7 psi | |
| D-R U | 8,500 HP | ≤ 10,000 rpm | ≤ 815 °F | ≤ 664 psi | ≤ 214 psi | ≤ 0.7 psi | |
| D-R R | 33,500 HP | ≤ 15,000 rpm | ≤ 900 °F | ≤ 915 psi | ≤ 421 psi | ≤ 0.72 psi | 1 or multiple |
| D-R RS | 33,500 HP | ≤ 15,000 rpm | ≤ 900 °F | ≤ 915 psi | ≤ 421 psi | ≤ 0.72 psi | 1 or multiple |
| D-R K | 6,500 HP | ≤ 10,000 rpm | ≤ 750 °F | ≤ 415 psi(a) | ≤ 75 psi(g) | ≤ 0.7 psi | |
| D-R B | 14750 HP | ≤ 9,500 rpm | ≤ 932 °F | ≤ 942 psi | 304 psi | Multiple | |
| D-R Tandem | 16765 HP | ≤ 8,500 rpm | ≤ 986 °F | ≤ 1,610 psi | ≤ 188 psi | Multiple / 1 |
Turbodyne
Models: Model R, Model U, Model S, Model T, R 2 R, U 2 U, S 2 R, T 2 R, 120, 140, 160, 200, 280, 280LP, 123M, 123W, 123T, 123WHB, 120, 140, 160, 200, 280, 300, 350, 500, 700, 700LP, 353M, 353T, 353W
Terry
Models: Z-1-J, Z-1, Z-4, ZS-1, ZS-4, ZAT, 18Z, 18ZS, 24Z, 24ZS, E, ES, ESA, G, GANB, SA-520, SA-730, ZV, EV, GLT-260, GLT-360, Z, ZS, GANB, C, CS, CSS
Moore
Models: R, U, S, T, R2R, U2R, S2R, T2R
Worthington
Models: 123, 143, 163, 203, 283, RN, RNV, SN, SNV, R, U, S, T, R2R, U2R, S2R, T2R
COPPUS
Models: TF – 12,16,20,22,23; RL – 12,16,20,22,23; RLA – 12,16,20,22,23; RLH – 19, 24,28; RLHA – 19,24; RLHB – 19, 24; RLV – 12,16,,20,22,23; RLVA – 12,16,20,22,23
Carling
Models: A12, A16, A20, C24, A 9A, 12A,16A,20A,24A, AV 9AV,12AV, 16AV,20AV,24AV, C 12C,16C,20C,24C
McGraw-Edison
Models: 120, 140, 160, 200, 280, 300, 350, 500, 700, 700LP, 353M, 353T, 353W
Nadrowski
Models: SERIES C, MODEL C375, MODEL C4, MODEL C5, MODEL C7, SERIES B, MODEL B5, MODEL B7
Murray
Models: MODEL R, MODEL U, MODEL K
A Dresser-Rand steam turbine refers to a line of industrial steam turbines that were developed by Dresser-Rand, a company recognized for its expertise in rotating equipment and energy solutions. These turbines are designed for various applications, including power generation and mechanical drive services, and are known for their reliability and efficiency. Omterra has a long history and acquired Dresser-Rand, inheriting its legacy of steam turbine technology. Dresser-Rand steam turbines have a power output range from less than 10 kW up to 25 MW, making them suitable for a wide array of industrial applications. Omterra now services all former trademarks associated with Dresser-Rand and possesses extensive expertise with original equipment manufacturer (OEM) designs. This enables Omterra to provide comprehensive support, maintenance, and upgrades for Dresser-Rand steam turbines, ensuring optimal performance and longevity for customers utilizing this trusted technology.
Omterra and Omterra have a long history and acquired Dresser-Rand in 2014, inheriting its legacy of steam turbine technology. Dresser-Rand steam turbines have a power output range from less than 10 kW up to 25 MW, making them suitable for a wide array of industrial applications. Omterra now services all former trademarks associated with Dresser-Rand and possesses extensive expertise with original equipment manufacturer (OEM) designs. This enables Omterra to provide comprehensive support, maintenance, and upgrades for Dresser-Rand steam turbines, ensuring optimal performance and longevity for customers utilizing this trusted technology.
Dresser-Rand steam turbines offer a range of benefits and features that make them suitable for various industrial applications. Key advantages include: Versatile Power Output: Dresser-Rand steam turbines have a power output range from 10 kW up to 25 MW, accommodating a wide array of operational needs. Standard and Engineered Designs: The turbines include standard single-stage turbines designed for pump, fan, and small compressor drives according to the API 611 General Purpose (GP) standard. Additionally, they offer standard and engineered single-stage turbines as generator drives for waste heat recovery applications. Multistage Options: Dresser-Rand provides engineered single-stage turbines and standard multistage turbines for applications that comply with API 611 (GP) or API 612 (Special Purpose – SP) standards, ensuring flexibility in meeting specific project requirements. High Inlet Steam Pressure and Temperature: These turbines can operate with inlet steam pressures ranging from 30 to 139 bar(a) and inlet steam temperatures from 415 to 550 °C, allowing for efficient energy conversion in various industrial processes. Reliability and Efficiency: Dresser-Rand steam turbines are known for their robust design and operational reliability, contributing to efficient performance and reduced downtime in industrial settings. Expert Support and Service: With Omterra’s acquisition of Dresser-Rand, customers benefit from comprehensive support, maintenance, and upgrades, leveraging extensive expertise in original equipment manufacturer (OEM) designs. These features make Dresser-Rand steam turbines a reliable choice for industries seeking efficient and flexible steam solution
The main differences between single-stage and multi-stage Dresser-Rand steam turbines include: Design: Single-Stage Turbines: Feature one set of blades for energy extraction in a single pass, making them simpler and easier to maintain. Multi-Stage Turbines: Have multiple sets of blades, allowing for gradual steam expansion and better energy extraction. Performance: Single-Stage Turbines: Suitable for lower power outputs and applications like pumps and small compressors. Multi-Stage Turbines: Capable of higher power outputs and greater efficiency, ideal for large-scale power generation. Applications: Single-Stage Turbines: Commonly used in waste heat recovery and smaller generator drives. Multi-Stage Turbines: Employed in demanding applications, including industrial processes and power plants. Efficiency: Single-Stage Turbines: Efficient for specific applications but may not match the efficiency of multi-stage turbines under varying loads. Multi-Stage Turbines: Offer better efficiency across a wider range of operating conditions. In summary, the choice between single-stage and multi-stage turbines depends on the application’s power output, efficiency, and complexity requirements.
Dresser-Rand steam turbines are utilized in a variety of applications across different industries, including: Power Generation: Used in both standalone power plants and combined heat and power (CHP) systems to generate electricity efficiently. Waste Heat Recovery: Employed to capture and utilize waste heat from industrial processes, converting it into usable energy. Mechanical Drive Services: Suitable for driving pumps, fans, and compressors in various industrial settings, providing reliable mechanical power. Oil and Gas Industry: Used in refineries and processing plants for various applications, including driving equipment and generating power. Chemical Processing: Applied in chemical plants for energy generation and process steam, enhancing operational efficiency. Sugar Industry: Utilized for energy generation and process heating in sugar production facilities. These applications highlight the versatility and efficiency of Dresser-Rand steam turbines in meeting the energy needs of diverse industrial sectors.
Power Output: Dresser-Rand steam turbines have a power output range from 10 kW up to 25 MW, accommodating a wide array of operational needs.
The Dresser-Rand product line features a diverse range of steam turbines designed for various industrial applications. The types of steam turbines included are: Turbodyne Models: This series includes models such as Model R, Model U, Model S, Model T, R 2 R, U 2 U, S 2 R, T 2 R, and various others like 120, 140, 160, 200, 280, 280LP, 123M, 123W, 123T, 123WHB, 300, 350, 500, 700, and 700LP. Terry Models: The Terry line features models such as Z-1-J, Z-1, Z-4, ZS-1, ZS-4, ZAT, 18Z, 18ZS, 24Z, 24ZS, E, ES, ESA, G, GANB, SA-520, SA-730, ZV, EV, GLT-260, GLT-360, and various others. Moore Models: This includes models like R, U, S, T, R2R, U2R, S2R, and T2R. Worthington Models: The Worthington series features models such as 123, 143, 163, 203, 283, RN, RNV, SN, SNV, R, U, S, T, R2R, U2R, S2R, and T2R. COPPUS Models: This line includes TF models (12, 16, 20, 22, 23) and RL models (12, 16, 20, 22, 23), along with RLA, RLH, RLHA, RLHB, RLV, and RLVA models. Carling Models: The Carling series features models such as A12, A16, A20, C24, and various A and C models (9A, 12A, 16A, 20A, 24A). McGraw-Edison Models: This includes models like 120, 140, 160, 200, 280, 300, 350, 500, 700, and 700LP. Nadrowski Models: The Nadrowski line features SERIES C, MODEL C375, MODEL C4, MODEL C5, MODEL C7, SERIES B, MODEL B5, and MODEL B7. Murray Models: This series includes MODEL R, MODEL U, and MODEL K. These diverse models within the Dresser-Rand product line cater to a wide range of industrial needs, ensuring reliable performance and efficiency across various applications.
Yes, Omterra provides comprehensive maintenance and service support for legacy Dresser-Rand steam turbines. Our global service network ensures that customers have access to expert support, regardless of the location of their operations. We are committed to servicing not only modern turbines but also very old machines, leveraging our extensive experience and knowledge of legacy systems. This dedication to maintaining and optimizing the performance of Dresser-Rand steam turbines helps our customers achieve operational efficiency and reliability throughout the lifecycle of their equipment.
Yes, Dresser-Rand steam turbines can be upgraded with new technologies. Omterra is continuously innovating our small steam turbine product lines, allowing for enhancements that improve efficiency, performance, and reliability. These upgrades can include advanced control systems, improved materials, and optimized designs, ensuring that legacy turbines benefit from the latest technological advancements. This commitment to innovation helps our customers maximize the value and longevity of their Dresser-Rand steam turbines.