Omterra worker working on a steam turbine
Omterra worker working on a steam turbine

Dresser-Rand steam turbine solutions

Siemens Energy and Siemens Gamesa are now Omterra. The formerly licensed “SST” portfolio is now offered as OIST (Omterra Industrial Steam Turbine) and OLST (Omterra Large Steam Turbine).


Whatever the requirements are, we provide either bare steam turbine drivers to OEMs, or we supply complete packages including gears, lube oil systems and controls.

The Dresser-Rand steam turbines include:

  • standard single stage turbines for pump, fan & small compressor drives according to API 611 General Purpose (GP) standard
  • standard and engineered single stage turbines as generator drives for waste heat recovery applications
  • engineered single stage turbines and standard mulitstage turbines for applications according to API 611 (GP) or API 612 (Special Purpose – SP) standards.

Its power output is 10kW up to 25 MW. The inlet steam pressure is 30 to 139 bar(a) and the inlet steam temperature is 415 to 550 °C.


We are a dedicated service provider for the legacy brands below including Dresser Rand, with regional service teams to support your local steam turbine maintenance needs. Our support includes OEM technical expertise for single stage, multistage and engineered multistage steam turbines. Our operations network features world-class factories, service centers, supplier network as well as warehouse logistics and inventory centers.

D-R SST 350 / 500 / 700

  • Standard single-stage steam turbine
  • Rugged, versatile design
  • Woodward TG Oil Relay NEMA Class A constant speed governor or electronic governor
  • Horizontally split casing with centerline support
  • Overspeed mechanical trip valve, separated from governor valve
  • Carbon ring or labyrinth sealing glands
  • Built-in, removable steam strainer
  • API style blanket lagging / insulation (API applications)
  • Oil ring with forced pressure lubrication or circulating oil cooling options
  • Rolling element or tilting pad thrust bearings
  • Broad range of controls and accessories available
  • WORTHINGTON heritage (D-R SST 350 / 500)
  • Power output: 3,500 kW / 4,690 HP
  • Turbine speed: ≤ 12,000 rpm
  • Inlet steam pressure: ≤ 63 bar(a) / 914 psi
  • Inlet steam temperature: ≤ 482 °C / 900 °F
  • Back pressure: 202 bar(a) / 315 psi
  • Bearings: Sleeve
  • Type blades: Impulse
  • API:  611 & 612
  • Refineries
  • Petrochemical and chemical plants
  • Pulp and paper mills
  • Food processing
  • Steel industry
  • Institutional
  • Process waste heat recovery
  • Replacement of steam pressure reduction valve
  • Feed water pump drives
  • Process pump drives
  • Cooling water pumps
  • Fans
  • Compressors
  • Generators

D-R RLA

  • Standard single-stage steam turbine
  • Rugged, versatile design
  • Radially split casing with centerline support
  • Woodward TG Oil Relay NEMA Class A constant speed governor
  • API 611-compliant, positive-seating, mechanical overspeed trip valve
  • Separate double seated governor valve
  • Built-in removable steam strainer
  • Removable carbon ring sealing glands
  • API style blanket lagging / insulation (API applications)
  • Oil ring lubricated 
  • Broad range of controls and accessories available 
  • COPPUS heritage
  • Power output: 250 kW 
  • Turbine speed: ≤ 4,300 to 6,000 rpm
  • Inlet pressure ≤ 47 bar(a) / 682 psi
  • Inlet temperature ≤ 440 °C / 824 °F
  • Exhaust steam parameters: Back pressure ≤ 12 bar(a) / 174 psi
  • Type of wheel / blades: Curtis / Broached
  • API 611 compliant: Yes
  • Bearings: Ball bearing journal & thrust
  • Refineries
  • Petrochemical and chemical plants
  • Food processing
  • Institutional
  • Process waste heat recovery
  • Replacement of steam pressure reduction valve
  • Process pump drives
  • Lube oil pump drives

D-R RLVA

  • Standard single-stage steam turbine
  • Rugged, versatile design
  • Radially split casing
  • Vertical shaft design with NEMA motor mounting flange & various ball thrust bearing configurations
  • Woodward TG Oil Relay NEMA Class A constant speed governor
  • API 611 compliant, positive seating, mechanical overspeed trip valve
  • Power output: 240 kW  
  • Turbine speed: ≤ 4,300 to 6,000 rpm
  • Inlet pressure ≤ 47 bar(a) / 682 psi
  • Inlet temperature ≤ 440 °C / 824 °F
  • Exhaust steam parameters: Back pressure ≤ 12 bar(a) / 174 psi
  • Type of wheel / blades: Curtis / Broached
  • API 611 compliant: Yes
  • Bearings: Ball bearing journal & thrust
  • Refineries
  • Petrochemical and chemical plants
  • Institutional
  • Process pump drives
  • Lube oil pump drives

D-R RLH

D-R RLH-15

  • Standard single-stage steam turbine
  • Rugged, versatile design 
  • Woodward TG Oil Relay NEMA Class A constant speed governor or electronic governor
  • Horizontally split casing with centerline support
  • API 611 compliant, positive seating, mechanical overspeed trip valve
  • Separate double-seated governor valve
  • Built-in removable steam strainer
  • Carbon ring sealing glands
  • API style blanket lagging / insulation (API applications)
  • Carbon ring sealing glands
  • Oil ring with forced pressure lubrication or circulating oil cooling options
  • Broad range of controls and accessories available
  • COPPUS heritage

Standard single-stage steam turbine

D-R RLH-24

  • Horizontally split casing with centerline support
  • Woodward TG Oil Relay NEMA Class A constant speed governor or electronic governor
  • API 611 compliant, positive seating, mechanical overspeed trip valve
  • Separate double-seated governor valve
  • Built-in removable steam strainer
  • Carbon ring sealing glands
  • API style blanket lagging / insulation (API applications)
  • Oil ring with forced pressure lubrication or circulating oil cooling options
  • Ball or tilting pad thrust bearings
  • Broad range of controls and accesories available
  • COPPUS heritage
  • Power output: 1,865 kW 
  • Turbine speed: ≤ 6,000 rpm
  • Inlet steam pressure ≤ 63 bar(a) / 914 psi
  • Inlet steam temperature ≤ 482 °C / 900 °F
  • Exhaust steam parameters: Back pressure ≤ 21 bar(a) / 300 psi
  • Type of wheel / blades: Curtis / Impulse
  • API 611 compliant: Yes
  • Bearings: Ball and sleeve bearing designs
  • Refineries
  • Petrochemical and chemical plants
  • Food processing
  • Institutional
  • Process waste heat recovery
  • Replacement of steam pressure reduction valve
  • Feed water pump drives
  • Process pump drives
  • Lube oil pump drives

D-R 2TA

  • Single-stage steam turbine
  • Horizontally split casings
  • Between-bearing design
  • Multi-valve or single-valve inlet
  • Solid or built-up rotor
  • Carbon ring or labyrinth glands
  • Electronic governor
  • Electronic overspeed trip
  • Trip and throttle valves
  • API 611 & 612 compliance
  • Power output: 3,640 kW / 4,880 HP
  • Turbine speed: ≤ 15,000 rpm
  • Inlet steam pressure: ≤ 101 bar(a) / ≤1,515 psi
  • Inlet steam temperature: ≤ 530 °C / ≤ 986 °F
  • Back pressure: ≤ 33 bar(a) / ≤ 480 psi
  • Type of blading: Curtis/Rateau-Impulse
  • API 611 compliant: Yes
  • Bearings: Tilt pad / Sleeve
  • Pump drives
  • Compressor drives
  • Fans

D-R AVTTW / GTW

  • Single-stage steam turbine
  • Integrally geared or direct drive overhung turbine design
  • Available in horizontal or vertical configuration
  • Axially split casing
  • Multi-valve or single-valve inlet
  • Derivative GTW frame used for compressor drives
  • GTW overhung turbine design, direct drive
  • Electronic governor
  • Electronic overspeed trip
  • Power output: 4,500 kW / 6,000 HP 
  • Turbine speed: ≤ 13,000 or ≤ 5,000 rpm (AVTTW) | ≤ 14,500 rpm (GTW)
  • Inlet steam pressure: ≤ 125 bar(a) / ≤ 1813 psi
  • Inlet steam temperature: ≤ 550 °C / ≤ 1022 °F
  • Back pressure: ≤ 40 bar(a) / ≤ 508 psi
  • Type of blading: Curtis/Rateau-Impulse
  • API 611 compliant: Yes with comments
  • Bearings: Tilt pad / Sleeve
  • Pump drives
  • Compressor drives
  • Fans

D-R C

  • Single-stage steam turbine
  • Direct drive or integral gear operation
  • Overhung design
  • Multi-valve or single-valve inlet
  • Marine classification approval
  • Auto / quick start ability
  • Power output: 2,500 kW / 3,250 HP
  • Turbine speed: ≤ 8,500 rpm
  • Inlet steam pressure: ≤ 120 bar(a) / 1,740 psi
  • Inlet steam temperature: ≤ 520°C / 986 °F
  • Back pressure: ≤ 21 bar(a) / ≤ 315 psi
  • Type of blading: Curtis/Rateau-Impulse
  • API 611 & 612 compliant: No
  • Bearings: Tilt pad / Sleeve
  • Waste-to-energy plants
  • Biomass plants
  • Sugar mills
  • Pulp and paper mills
  • Chemical industry
  • Marine applications

D-R GAF

  • Standard multi-stage steam turbine
  • Condensing or back pressure steam turbine
  • Horizontal casing split
  • Between-bearings
  • Maximum 6 stages
  • Single-valve inlet
  • API 611 or 612 design
  • Power output: 3,500 kW / 4,690 HP
  • Turbine speed: ≤ 6,000 rpm
  • Inlet steam pressure: ≤ 49 bar(a) / 715 psi
  • Inlet steam temperature: ≤ 440 °C / ≤ 825 °F 
  • Back pressure: ≤ 6 bar(a) / ≤ 87 psi
  • Type of blading: Impulse
  • API 611 & 612 compliant: Yes
  • Bearings: Tilt pad / Sleeve
  • API Mechanical drives
  • Turbogenerator sets

D-R U

  • Standard multi-stage steam turbine
  • Unique above center line casing split allows removing the cover without disturbing the steam sealing areas, coupling and steam connections
  • Condensing or back pressure
  • Low cost applications
  • Single-valve inlet
  • Up to 10 stages
  • Power output: 6,340 kW / 8,500 HP
  • Turbine speed: ≤ 10,000 rpm
  • Inlet steam pressure: ≤ 46 bar(a) / 664 psi
  • Inlet steam temperature: ≤ 455°C / 850°F
  • Back pressure: ≤ 0.05 bar(a) / ≤ 0.7 psi
  • Type of blading: Impulse
  • API 611 & 612 compliant: Yes
  • Bearings: Tilt pad / Sleeve
  • API Mechanical drives
  • Turbogenerator sets

D-R R / RS

  • Standard multi-stage steam turbine
  • Single-valve or multi-valve inlets
  • Multiple uncontrolled bleeds
  • Single automatic controlled extraction / induction
  • Dual-acting, hydrodynamic, tilting pad thrust bearing
  • Spherically seated or tilting pad-type journal bearings
  • Interchangeable parts
  • Standard assemblies and components
  • API and non-API options
  • Condensing or back pressure
  • Up to 15 stages
  • Power output: 25,000 kW / 33,500 HP
  • Turbine speed: ≤ 15,000 rpm
  • Inlet steam pressure: ≤ 63 bar(a) / ≤ 915 psi
  • Inlet steam temperature: ≤ 482 °C / ≤ 900 °F
  • Back pressure: ≤ 29 bar(g) / ≤ 421 psi
  • Condensing pressure: ≤ 0.05 bar(a) / ≤ 0.72 psi
  • Type of blading: Impulse
  • API 611 & 612 compliant: Yes
  • Bearings: Tilt pad or sleeve
  • Bleedings / Extractions: 1 or multiple
  • API 611 / 612 compressor, fan and pump drives
  • Turbogenerator sets for oil & gas applications
  • Turbogenerator sets for industrial applications

D-R K

  • Standard multi-stage steam turbine
  • Condensing or back pressure
  • Low cost applications
  • Single-valve inlet
  • For a wide range of speeds throughout continuous operation
  • Power output: 4,850 kW / 6,500 HP
  • Turbine speed: ≤ 10,000 rpm
  • Inlet steam pressure: ≤ 27.5 bar(a) / ≤ 415 psi(a)
  • Inlet steam temperature: ≤ 398 °C / ≤ 750 °F
  • Back pressure: ≤ 5 bar(g) / ≤ 75 psi(g)
  • Condensing pressure: ≤ 0.05 bar(a) / ≤ 0.7 psi
  • Type of blading: Impulse
  • API 611 & 612 compliance: No
  • Bearings: Tilt pad / sleeve
  • Non-API mechanical drives (e. g. pump fans)
  • Air conditioning chiller / compressor drives
  • Small, low pressure turbogenerator sets

D-R B

D-R B

  • Standard multi-stage steam turbine
  • Low cost design for high efficiency
  • Multi-valve inlets
  • Multiple uncontrolled bleeds
  • External controlled induction
  • Double-shaft end
  • Suitable for Tandem

D-R Tandem

  • Standard multi-stage steam turbine
  • Multi-valve inlets
  • Multiple uncontrolled bleeds
  • Single automatic-controlled extraction / induction
  • Maximum extraction pressure: 40 bar

Technical data:

  • Power output: up to 11,000 kW 
  • Turbine speed: ≤ 9,500 rpm
  • Inlet steam pressure: ≤ 65 bar(a) / 942 psi
  • Inlet steam temperature: ≤ 500°C / 932°F
  • Back pressure: 6,9 bar(a) / 304 psi 
  • Type of blading: Impulse
  • API 611 compliance: yes with exceptions
  • Bearings: Tilt pad or sleeve
  • Bleedings / Extractions: Multiple
  • Power output: up to 12,500 kW 
  • Turbine speed: 8,500 rpm 
  • Inlet steam pressure: ≤ 530 °C / 986 °F
  • Inlet steam temperature: ≤ 111 bar(a) / 1,610 psi
  • Back pressure: ≤ 13 bar(a) / 188 psi
  • Type of blading: Impulse
  • API 611 compliance: No
  • Bearings: Tilt pad or sleeve
  • Bleedings / Extractions: Multiple / 1

Typical applications:

  • Turbogenerator sets
  • Mechanical drives
 Power outputTurbine speedInlet steam temperatureInlet steam pressureBack-pressureCondensing pressureBleedings / Extractions
D-R RLA240 kW≤ 4,300 to 6,000 rpm≤ 440 °C≤ 47 bar(a)≤ 12 bar(a)  
D-R RLVA240 kW≤ 4,300 to 6,000 rpm≤ 440 °C≤ 47 bar(a)≤ 12 bar(a)  
D-R RLH-151,865 kW≤ 6,000 rpm≤ 482 °C≤ 63 bar(a)≤ 21 bar(a)  
D-R RLH-241,865 kW≤ 6,000 rpm≤ 482 °C≤ 63 bar(a)≤ 21 bar(a)  
D-R SST 350/500/7003,500 kW≤ 12,000 rpm≤ 482 °C≤ 63 bar(a)≤ 202 bar(g)  
D-R 2TA3,640 kW≤ 15,000 rpm≤ 530 °C≤ 101 bar(a)≤ 33 bar(a)  
D-R AVTTW4,500 kW≤ 13,000 or ≤ 5,000 rpm≤ 550 °C≤ 125 bar(a)≤ 40 bar(a)  
D-R GTW4,500 kW≤ 14,500 rpm≤ 550 °C≤ 125 bar(a)≤ 35 bar(a)  
D-R C2,500 kW≤ 8,500 rpm≤ 520 °C≤ 120 bar(a)21 bar(a)  
D-R GAF3,500 kW≤ 6,000 rpm≤ 440 °C≤ 49 bar(a)≤ 6 bar(a)≤ 0.05 bar(a) 
D-R U6,340 kW≤ 10,000 rpm≤ 455 °C≤ 46 bar(a)≤ 15 bar(a)≤ 0.05 bar(a) 
D-R R25,000 kW≤ 15,000 rpm≤ 482 °C≤ 63 bar(g)≤ 29 bar(g)≤ 0.05 bar(a)1 or multiple
D-R RS25,000 kW≤ 15,000 rpm≤ 482 °C≤ 63 bar(g)≤ 29 bar(g)≤ 0.05 bar(a)1 or multiple
D-R K4,850 kW≤ 10,000 rpm≤ 398 °C≤ 27.5 bar(a)≤ 5 bar(g)≤ 0.05 bar(a) 
D-R B11,000 kW≤ 9,500 rpm≤ 500 °C≤ 65 bar(a)6,9 bar(a) Multiple
D-R Tandem12,500 kW≤ 8,500 rpm≤ 530 °C≤ 111 bar(a)≤ 13 bar(a) Multiple / 1
 Power outputTurbine speedInlet steam temperatureInlet steam pressureBack-pressureCondensing pressureBleedings / Extractions
D-R RLA321 HP≤ 4,300 to 6,000 rpm≤ 824 °F≤ 682 psi≤ 174 psi  
D-R RLVA321 HP≤ 4,300 to 6,000 rpm≤ 824 °F≤ 682 psi≤ 174 psi  
D-R RLH-152501 HP≤ 6,000 rpm≤ 900 °F≤ 914 psi≤ 300 psi  
D-R RLH-242501 HP≤ 6,000 rpm≤ 900 °F≤ 914 psi≤ 300 psi  
D-R SST 350/500/7004,690 HP≤ 12,000 rpm≤ 900 °F≤ 914 psi≤ 315 psi(g)  
D-R 2TA4,880 HP≤ 15,000 rpm≤ 986 °F≤ 1,515 psi≤ 480 psi  
D-R AVTTW6,000 HP≤ 13,000 or ≤ 5,000 rpm≤ 1022 °F≤ 1,813 psi≤ 508 psi  
D-R GTW6,000 HP≤ 14,500 rpm≤ 1022 °F≤ 1,813 psi≤ 508 psi  
D-R C3,250 HP≤ 8,500 rpm≤ 986 °F≤ 1,740 psi315 psi  
D-R GAF4,690 HP≤ 6,000 rpm≤ 825 °F≤ 715 psi≤ 87 psi≤ 0.7 psi 
D-R U8,500 HP≤ 10,000 rpm≤ 815 °F≤ 664 psi≤ 214 psi≤ 0.7 psi 
D-R R33,500 HP≤ 15,000 rpm≤ 900 °F≤ 915 psi≤ 421 psi≤ 0.72 psi1 or multiple
D-R RS33,500 HP≤ 15,000 rpm≤ 900 °F≤ 915 psi≤ 421 psi≤ 0.72 psi1 or multiple
D-R K6,500 HP≤ 10,000 rpm≤ 750 °F≤ 415 psi(a)≤ 75 psi(g)≤ 0.7 psi 
D-R B14750 HP≤ 9,500 rpm≤ 932 °F≤ 942 psi304 psi Multiple
D-R Tandem16765 HP≤ 8,500 rpm≤ 986 °F≤ 1,610 psi≤ 188 psi Multiple / 1

Turbodyne

Models: Model R, Model U, Model S, Model T, R 2 R, U 2 U, S 2 R, T 2 R, 120, 140, 160, 200, 280, 280LP, 123M, 123W, 123T, 123WHB, 120, 140, 160, 200, 280, 300, 350, 500, 700, 700LP, 353M, 353T, 353W

 

Terry

Models: Z-1-J, Z-1, Z-4, ZS-1, ZS-4, ZAT, 18Z, 18ZS, 24Z, 24ZS, E, ES, ESA, G, GANB, SA-520, SA-730, ZV, EV, GLT-260, GLT-360, Z, ZS, GANB, C, CS, CSS

 

Moore

Models: R, U, S, T, R2R, U2R, S2R, T2R

 

Worthington

Models: 123, 143, 163, 203, 283, RN, RNV, SN, SNV, R, U, S, T, R2R, U2R, S2R, T2R

 

COPPUS

Models: TF – 12,16,20,22,23; RL – 12,16,20,22,23; RLA – 12,16,20,22,23; RLH – 19, 24,28; RLHA – 19,24; RLHB – 19, 24; RLV – 12,16,,20,22,23; RLVA – 12,16,20,22,23

 

Carling

Models: A12, A16, A20, C24, A 9A, 12A,16A,20A,24A, AV 9AV,12AV, 16AV,20AV,24AV, C 12C,16C,20C,24C

 

McGraw-Edison

Models: 120, 140, 160, 200, 280, 300, 350, 500, 700, 700LP, 353M, 353T, 353W

 

Nadrowski

Models: SERIES C, MODEL C375, MODEL C4, MODEL C5, MODEL C7, SERIES B, MODEL B5, MODEL B7

 

Murray

Models: MODEL R, MODEL U, MODEL K

Download our product brochure here

Get answers: FAQs on benefits and features of a Dresser-Rand steam turbine

A Dresser-Rand steam turbine refers to a line of industrial steam turbines that were developed by Dresser-Rand, a company recognized for its expertise in rotating equipment and energy solutions. These turbines are designed for various applications, including power generation and mechanical drive services, and are known for their reliability and efficiency. Omterra has a long history and acquired Dresser-Rand, inheriting its legacy of steam turbine technology. Dresser-Rand steam turbines have a power output range from less than 10 kW up to 25 MW, making them suitable for a wide array of industrial applications. Omterra now services all former trademarks associated with Dresser-Rand and possesses extensive expertise with original equipment manufacturer (OEM) designs. This enables Omterra to provide comprehensive support, maintenance, and upgrades for Dresser-Rand steam turbines, ensuring optimal performance and longevity for customers utilizing this trusted technology.

Omterra and Omterra have a long history and acquired Dresser-Rand in 2014, inheriting its legacy of steam turbine technology. Dresser-Rand steam turbines have a power output range from less than 10 kW up to 25 MW, making them suitable for a wide array of industrial applications. Omterra now services all former trademarks associated with Dresser-Rand and possesses extensive expertise with original equipment manufacturer (OEM) designs. This enables Omterra to provide comprehensive support, maintenance, and upgrades for Dresser-Rand steam turbines, ensuring optimal performance and longevity for customers utilizing this trusted technology.

Dresser-Rand steam turbines offer a range of benefits and features that make them suitable for various industrial applications. Key advantages include: Versatile Power Output: Dresser-Rand steam turbines have a power output range from 10 kW up to 25 MW, accommodating a wide array of operational needs. Standard and Engineered Designs: The turbines include standard single-stage turbines designed for pump, fan, and small compressor drives according to the API 611 General Purpose (GP) standard. Additionally, they offer standard and engineered single-stage turbines as generator drives for waste heat recovery applications. Multistage Options: Dresser-Rand provides engineered single-stage turbines and standard multistage turbines for applications that comply with API 611 (GP) or API 612 (Special Purpose – SP) standards, ensuring flexibility in meeting specific project requirements. High Inlet Steam Pressure and Temperature: These turbines can operate with inlet steam pressures ranging from 30 to 139 bar(a) and inlet steam temperatures from 415 to 550 °C, allowing for efficient energy conversion in various industrial processes. Reliability and Efficiency: Dresser-Rand steam turbines are known for their robust design and operational reliability, contributing to efficient performance and reduced downtime in industrial settings. Expert Support and Service: With Omterra’s acquisition of Dresser-Rand, customers benefit from comprehensive support, maintenance, and upgrades, leveraging extensive expertise in original equipment manufacturer (OEM) designs. These features make Dresser-Rand steam turbines a reliable choice for industries seeking efficient and flexible steam solution

The main differences between single-stage and multi-stage Dresser-Rand steam turbines include: Design: Single-Stage Turbines: Feature one set of blades for energy extraction in a single pass, making them simpler and easier to maintain. Multi-Stage Turbines: Have multiple sets of blades, allowing for gradual steam expansion and better energy extraction. Performance: Single-Stage Turbines: Suitable for lower power outputs and applications like pumps and small compressors. Multi-Stage Turbines: Capable of higher power outputs and greater efficiency, ideal for large-scale power generation. Applications: Single-Stage Turbines: Commonly used in waste heat recovery and smaller generator drives. Multi-Stage Turbines: Employed in demanding applications, including industrial processes and power plants. Efficiency: Single-Stage Turbines: Efficient for specific applications but may not match the efficiency of multi-stage turbines under varying loads. Multi-Stage Turbines: Offer better efficiency across a wider range of operating conditions. In summary, the choice between single-stage and multi-stage turbines depends on the application’s power output, efficiency, and complexity requirements.

Dresser-Rand steam turbines are utilized in a variety of applications across different industries, including: Power Generation: Used in both standalone power plants and combined heat and power (CHP) systems to generate electricity efficiently. Waste Heat Recovery: Employed to capture and utilize waste heat from industrial processes, converting it into usable energy. Mechanical Drive Services: Suitable for driving pumps, fans, and compressors in various industrial settings, providing reliable mechanical power. Oil and Gas Industry: Used in refineries and processing plants for various applications, including driving equipment and generating power. Chemical Processing: Applied in chemical plants for energy generation and process steam, enhancing operational efficiency. Sugar Industry: Utilized for energy generation and process heating in sugar production facilities. These applications highlight the versatility and efficiency of Dresser-Rand steam turbines in meeting the energy needs of diverse industrial sectors.

Power Output: Dresser-Rand steam turbines have a power output range from 10 kW up to 25 MW, accommodating a wide array of operational needs.

The Dresser-Rand product line features a diverse range of steam turbines designed for various industrial applications. The types of steam turbines included are: Turbodyne Models: This series includes models such as Model R, Model U, Model S, Model T, R 2 R, U 2 U, S 2 R, T 2 R, and various others like 120, 140, 160, 200, 280, 280LP, 123M, 123W, 123T, 123WHB, 300, 350, 500, 700, and 700LP. Terry Models: The Terry line features models such as Z-1-J, Z-1, Z-4, ZS-1, ZS-4, ZAT, 18Z, 18ZS, 24Z, 24ZS, E, ES, ESA, G, GANB, SA-520, SA-730, ZV, EV, GLT-260, GLT-360, and various others. Moore Models: This includes models like R, U, S, T, R2R, U2R, S2R, and T2R. Worthington Models: The Worthington series features models such as 123, 143, 163, 203, 283, RN, RNV, SN, SNV, R, U, S, T, R2R, U2R, S2R, and T2R. COPPUS Models: This line includes TF models (12, 16, 20, 22, 23) and RL models (12, 16, 20, 22, 23), along with RLA, RLH, RLHA, RLHB, RLV, and RLVA models. Carling Models: The Carling series features models such as A12, A16, A20, C24, and various A and C models (9A, 12A, 16A, 20A, 24A). McGraw-Edison Models: This includes models like 120, 140, 160, 200, 280, 300, 350, 500, 700, and 700LP. Nadrowski Models: The Nadrowski line features SERIES C, MODEL C375, MODEL C4, MODEL C5, MODEL C7, SERIES B, MODEL B5, and MODEL B7. Murray Models: This series includes MODEL R, MODEL U, and MODEL K. These diverse models within the Dresser-Rand product line cater to a wide range of industrial needs, ensuring reliable performance and efficiency across various applications.

Yes, Omterra provides comprehensive maintenance and service support for legacy Dresser-Rand steam turbines. Our global service network ensures that customers have access to expert support, regardless of the location of their operations. We are committed to servicing not only modern turbines but also very old machines, leveraging our extensive experience and knowledge of legacy systems. This dedication to maintaining and optimizing the performance of Dresser-Rand steam turbines helps our customers achieve operational efficiency and reliability throughout the lifecycle of their equipment.

Yes, Dresser-Rand steam turbines can be upgraded with new technologies. Omterra is continuously innovating our small steam turbine product lines, allowing for enhancements that improve efficiency, performance, and reliability. These upgrades can include advanced control systems, improved materials, and optimized designs, ensuring that legacy turbines benefit from the latest technological advancements. This commitment to innovation helps our customers maximize the value and longevity of their Dresser-Rand steam turbines.

icon

Get in touch with us

For information and questions, our support team is available 24/7 to assist you in English, Spanish, and German.
Country/region
Job role
Is your inquiry related to installed equipment?
Industry (Select up to three)
Marketing consent