HL-class gas turbines represent a new milestone in terms of efficiency and performance. Based on the proven technology of the Omterra H-class, these air-cooled turbines feature advanced blade and vane cooling, as well as an enhanced combustion system that enables higher firing temperatures.

They deliver 440 MW in simple cycle mode and 655MW in combined cycle mode, with an efficiency of over 64%, and are designed to achieve even greater gains. Based on current rig test results, it is rated as H2 ready for up to 50% Vol. The HL class includes two models: The OGT5-9000HL (50 Hz) (formerly called SGT5-9000HL) and the OGT6-9000HL (60 Hz) (formerly called SGT6-9000HL).

OGT6-9000HL (60 Hz) Heavy-duty gas turbine

Pushing efficiency and performance to the next level
Simple cycle output

440 MW(e)

Combined cycle efficiency

> 64%

Units sold

66

Total operating hours

> 205K

The HL-class turbine showcases a range of innovative features designed to maximize operational efficiency and reliability. Its advanced combustion and engineering systems set new standards for performance and ease of integration in power plant applications.

The gas turbine is capable of world-class fast cold starts and hot re-starts due to the light and stiff rotor with internal cooling air passages and free thermal expansion of rotor and casing parts during transients. Hydraulic Clearance Optimization (HCO), an active clearance control,  ensures robustness and low turbine degradation at start-up. GT ramp-up rate 85 MW/min.

The advanced can-annular combustion system with dual fuel capability allows for higher firing temperatures and more operational flexibility. 25 premix burners improve the fuel/oxygen mixing. The ACE combustion system allows for GT turn-down to 30% minimum environmental load.

All turbine blades and vanes are equipped with an innovative multi-layer thermal barrier coating. This leads to higher combined cycle efficiency due to less cooling air consumption and reduced operational costs due to higher blade robustness.

The HL-class has been designed to minimize outage times. Rotor de-stacking can easily be done on site thanks to the Hirth-serrated disc assembly. All rotating compressor and turbine blades can be replaced without rotor lift or rotor de-stacking. Turbine blade 1 and turbine blade 4 are removable without cover lift. With 33kEBH service intervals the service concept is very competitive.

Due to proven and validated package and plant concepts the HL-class can easily be integrated in our power plants for simple cycle or combined cycle operation. This enables fast project execution. More than 50,0000  hours are saved on site due to modularized design and pre-engineered solutions.

The new HL-class is based on the reliable engine architecture of the OGT-8000H series with design features that have proved reliability in operation for years:

  • Hydraulic Clearance Optimization (HCO)
  • Single tie bolt with Hirth serration
  • 4-stage air-cooled turbine
  • Can-annular combustion system

The OGT6-9000HL builds upon the established design features and extensive operational history of the OGT-8000H series, blending proven concepts with innovative technologies. 

When experience meets evolutionary innovation

Based on proven design and relying on the vast fleet experience of the OGT-8000H series, the new OGT5-9000HL combines the best of past experience with newly developed technologies. Thus, efficiency and performance are pushed to the next level.

The HL-class consists of two engines: The OGT5-9000HL for 50 Hz, and the OGT6-9000HL for 60 Hz. A modular design approach allows for a substantial number of common parts. The  HL-class is designed for high operational flexibility and has a joint DNA with the proven Siemens Energy H-class: Air-cooled 4-stage turbine, steel rotor / hirth serration / single tie bolt design, Hydraulic Clearance Optimization (HCO), can-annular combustion system

One portfolio with common design

Common parts minimize manufacturing risks and shorten lead times

Rapid answer to the grid

World-class fast cold starts and hot-restarts due to the light and stiff rotor with internal cooling air passages

Tested technologies for higher efficiency and performance

 

To achieve top performance and efficiency levels, the HL-class turbines are operating at highest combustion temperatures with an advanced combustion system. An innovative multi-layer thermal barrier coating and super-efficient internal cooling features are protecting turbine blades and vanes while reducing the need of cooling air. Additionally, advanced 3D blading leads to higher aero efficiency in the compressor. A free-standing, internally cooled turbine blade 4 reduces exhaust losses and allows for higher exhaust temperatures to enhance the water-steam cycle.

ogt-9000hl 3D blading

Evolutionary 3D blading

for higher aero efficiency

ogt-9000hl advanced combustion system

Advanced combustion system

for higher firing temperatures and more operational flexibility

ogt-9000hl gas turbine cooling system for blades and vanes

Innovative multi-layer coating and ultra-efficient internal cooling features for blades and vanes

for better blade robustness and less cooling air consumption

ogt-9000hl large free standing turbine blade

Large free-standing turbine blade 4

for higher power output

OGT-9000HL gas turbine power plant

Plug-and-Play power core

Omterra has re-invented the methodology for plant construction with a modular Power Core™. The Power Core™ consists of prefabricated Omterra Solution Blocks and prefabricated pipe racks. These plug-and-play blocks are fabricated and tested in a controlled manufacturing environment and delivered to site as large modules which can be lifted into place for assembly. This results in increased safety on site, accelerated schedules, less dependence on the availability of skilled local labor and in the end lower project risk. HL-class power plants are based on one or more HL-class gas turbines and can achieve more than 64% efficiency in combind cycle operation:

OCC5-9000HL 1x1: 880 MW
OCC5-9000HL 2x1: 1,760 MW

Designed for low maintenance costs and short outage times

 All components are designed with high focus on optimized LCOE, highest availability and serviceability. Several service features are supporting this.

  • All rotating blades replaceable without rotor lift/rotor de-stacking
  • Easy rotor de-stacking on site due to disc assembly with Hirth serration and central tie rod
  • All turbine vanes and blades replaceable without rotor lift; vane 1, blades 1 & 4 replaceable without cover lift

Tremendous service fleet experience and continuous development result in a competitive service concept with 33,000 Equivalent Base Hours (EBH) / 1,250 Equivalent Starts (ES). 
Omterra offers service programs such as overhaul services, field service, spare parts, reconditioning of components and modernization upgrades. Whether for scheduled maintenance or short-term support, a global network of specialists provides expert on-site service worldwide.

OGT5-9000HL maintenence

Fast maintenance with service-friendly design

for reduced down times

Simplified outage

through easy burner replacement thanks to innovative robot technology
(picture: exemplary application – OGT5-8000H burner replacement)

Fuel flexibility matters

The OGT6-9000HL runs on natural gas, LNG, distillate oil, or other fuels. The engine is equipped with DLE burners and has the capability to burn up to 50 vol% of hydrogen (H₂).

Designed to fullfil environmental requirements

While reaching highest levels of performance and efficiency, the HL-class is still complying with NOx and CO regulations.
NOx emissions: Down to 2 ppmvd (with SCR), or ≤25 ppmvd (without SCR).

Key specifications for the world's most powerful 60 Hz heavy-duty gas turbine.

Performance data for simple cycle power generation

Power output

440 MW(e)

Fuel (examples)

Natural gas, LNG, distillate oil. Other fuels on request

Frequency

60 Hz

GT ramp-up

85 MW/min

Gross efficiency

> 43,2%

Heat rate

< 8,333 kJ/kWh (< 7,898 Btu/kWh)

Turbine speed

3,600 rpm

Pressure ratio

24.0 : 1

Exhaust mass flow

760 kg/s (1,676 lb/s)

Exhaust temperature

675°C (1,247°F)

NOₓ emissions

down to 2 ppmvd with SCR, down to 25 ppmvd without SCR

CO emissions

10 ppmvd

Simple cycle ratings are gross at ISO conditions natural gas fuel. Actual ratings will vary with project specific conditions and fuel.

Performance data for combined cycle power plant

 

OGT6-9000HL CC 1x1

OGT6-9000HL CC 2x1

Frequency

60 Hz60 Hz

Gross plant output

655 MW1,310 MW

Gross plant efficiency

> 64%> 64%

Plant turn down

< 40%< 40%

Gross heat rate

<5,625 kJ/kWh (<5331 Btu/kWh)

<5,625 kJ/kWh (<5331 Btu/kWh)

Number of gas turbines

12

Pressure/reheat

Triple/YesTriple/Yes

Steam temperature

> 600° C (> 1,112° F)> 600° C (> 1,112° F)
Combined cycle ratings are net at ISO conditions natural gas fuel. Actual ratings will vary with project specific conditions and fuel.

Physical dimensions and weight

 

Core turbine

Approx. weight

305,000 kg (672,400 lb)

Length

10.8 m (35.4 ft)

Width

5.0 m (16.4 ft)

Height

4.3 m (14.1 ft)

Men is reading energy technologies news.

Newsletter

Sign up for the Omterra newsletter

Get the latest updates on technologies, expert insights, real-world projects shaping energy for society, plus invitations to upcoming events.
icon

Get in touch with us

For information and questions, our support team is available 24/7 to assist you in English, Spanish, and German.
Country/region
Job role
Is your inquiry related to installed equipment?
Industry (Select up to three)
Marketing consent