The proven Omterra OGT6-5000F (formerly called SGT6-5000F) gas turbine offers economical power generation with fast start-up and quick load changes for peak, intermediate, or base load. Its outstanding fuel flexibility makes it a great gas turbine for many applications in the oil and gas industry.
With only single-digit NOₓ emissions (< 9 ppmvd), the OGT6-5000F provides world-class emission performance. To date, over 480 turbines have been sold worldwide The installed fleet has accumulated over 27 million operating hours, achieving a reliability rate of over 99%.
260 MW(e)
60.6%
480
>27M
>99%
The OGT6-5000F gas turbine is a proven engine for the 60 Hz market, with a power output of up to 260 MW and 40.6% simple cycle efficiency. Due to its robust turbine design, it provides rapid start-up and shutdown capabilities, with only 5 minutes from turning gear to full speed and a load gradient of up to 40 MW/min.
Due to its advanced combustion technology, single-digit emissions in base and part load can be achieved: NOₓ emissions of < 9 ppmvd and CO emissions of < 4 ppmvd. It can operate the OGT6-5000F at 30% part load in low load turndown over a wide range of ambient conditions, all within the emission limit values.
By using proven technology, low firing temperatures and conventionally cast alloys, this gas turbine achieves outstanding availability. Its robust turbine design is continuously enhanced by high-performance upgrades.
The OGT6-5000F is able to burn a wide range of fuels including natural gas, LNG, syngas, ethane, propane, Arabian Super Light crude oil, distillate oil, condensate, Arabian Extra Light crude oil, biodiesel, alcohols, Jet-A oil, and kerosene.
The engine offers dual fuel capability and tolerates fuels within a wide Wobbe range.
The combustion system is able to handle different fuel compositions, e.g. contents of hydrogen sulfide (H₂S) of up to 4,000 ppm, or hydrogen (H2) of up to 30 vol%. Its system can switch over quickly between fuel gas and fuel oil and vice versa.
The proven, low-risk design translates into longer service intervals and service life for your gas turbine. All rotating blades are replaceable without de-stacking or lifting the rotor.
Extensive experience in commercial operation means that you can rely on proven and validated package and plant concepts that enable early power generation in simple cycle. Projects are implemented quickly, fast project execution due to modularized package and plant design and pre-engineered solutions.
The OGT6-5000F gas turbine offers economical power generation. It has fast start-up. It is suitable for peak, intermediate or base load duty.
The OGT6-5000F features a 13-stage axial compressor with advanced 3D blade design. Three rows of variable guide vanes enable improved part load efficiency and transient operation. The rotor design of the 260 MW version is based on a single tie rod with Hirth serrations for reliable torque transmission.
Variable inlet guide vanes plus three stages of fast-acting variable guide vanes improve the part load efficiency of the 260 MW engine.
The 4-stage turbine uses proven, conventional materials to maximize maintenance intervals and availability.
The gas turbine package for the OGT6-5000F consists of the core turbine, the generator and auxiliary systems. A standardized basic design is provided, along with options that are tailored to meet specific requirements and market environments. This approach ensures operating costs remain as low as possible while providing maximum flexibility to accommodate individual requirements.
Designed for short installation times, all package piping is prefabricated to minimize pipe cleaning and welding on site.
Package footprint:
The packages include the gas turbine, generator, air intake system, exhaust gas system, auxiliary systems, power control center, instrumentation and control, and electrical systems.
Combined-cycle plants based on the OGT6-5000F offer fast start-up capability, reaching combined-cycle base-load operation within five minutes from a hot start. High load gradients (40 MW/min) allow for fast load changes. With excellent peaking capability, and high part load efficiency complying with emission regulations down to lower part load, it is a profitable solution for competitive energy markets with fluctuating power demand.
The OGT6-5000F multi-shaft combined cycle plants can be based on one (OCC6-5000F 1x1), two (OCC6-5000F 2x1) or more F-class gas turbines.
With its high steam raising capability, the OGT6-5000F is excellently suited for cogeneration or CHP applications, e.g., for
For combined-cycle and combined heat and power (CHP) applications, the solution can be integrated with condensing or backpressure steam turbines, with optional steam extraction to meet specific process and power generation requirements.
Omterra offers service programs such as overhaul services, field service, spare parts, reconditioning of components and modernization upgrades. Scheduled services and short-term support are available on-site all over the world.
Omterra is continuously improving the OGT6-5000F gas turbines, and upgraded parts are retrofittable into the existing fleet.
Our design strives to achieve a long service life for your gas turbine while minimizing risk. Thanks to low firing temperatures we can use proven conventional turbine alloys to prolong service intervals and service life.
All rotating blades can be replaced without de-stacking or lifting of the rotor.
The OGT6-5000F is designed to use a wide range of fuels: natural gas, LNG, syngas, ethane, propane, Arabian Super Light crude oil, distillate oil, condensate, Arabian Extra Light crude oil, biodiesel, alcohols, Jet-A oil, and kerosene.
The engine, equipped with DLE burners, is capable to burn up to 30 vol% of hydrogen (H2).
With the OGT6-5000F combustion system there is no need to shut down when switching from gas to liquid fuel and vice versa.
The annular combustion system is able to handle a wide range of fuels and creates a stable combustion with uniform flow and temperature distribution.
This gas turbine is equipped with a Low-NOₓ (ULN) combustion system for ultra-low NOₓ emissions.
The OGT6-5000F sets a benchmark in the industry, demonstrating < 9 ppmvd NOₓ emissions on fuel gas, with CO emission compliance down to 30% part load.
The OGT6-5000F offers clean combustion for a wide variety of fuels.
Key specifications for the world's most reliable 60 Hz heavy-duty gas turbine.
| 260 MW version | |
|---|---|
| Power output | 260MW(e) |
| Fuel (examples) | Natural gas, LNG, syngas, ethane, propane, Hydrogen blends up to 30% vol., distillate oil, bio-diesel, Arabian Super Light crude oil (ASL), Arabian Extra Light crude oil (AXL), condensate, alcohols, Jet-A oil and kerosene. Other fuels on request. |
| Frequency | 60 Hz |
| Gross efficiency | 40.6% |
| Heat rate | 8,870 kJ/kWh (8,400 Btu/kWh) |
| Turbine speed | 3,600 rpm |
| Pressure ratio | 19.5:1 |
| Exhaust mass flow | 587 kg/s (1,292 lb/s) |
| Exhaust temperature | 589°C (1,092°F) |
| NOₓ emissions on fuel gas | ≤ 9 ppmvd (without water injection for NOₓ control) |
| NOₓ emissions on fuel oil | ≤ 25 ppmvd (with water injection for NOₓ control) |
| 260 MW version | |
|---|---|
| Gross plant power output | 398 MW(e) |
| Gross plant efficiency | 60.5% |
| Gross heat rate | 5,950 kJ/kWh (5,640 Btu/kWh) |
| Number of gas turbines | 1 |
| Pressure/reheat | Triple/Yes |
| 260 MW version | |
|---|---|
| Gross plant power output | 798 MW(e) |
| Gross plant efficiency | 60.60% |
| Gross heat rate | 5,940 kJ/kWh (5,630 Btu/kWh) |
| Number of gas tubines | 2 |
| Pressure/reheat | Triple/Yes |
| Core engine 260 MW version | |
|---|---|
| Approx. weight | 219,000 kg (483,000 lb) |
| Length | 10.1 m (33 ft) |
| Width | 4.6 m (15 ft) |
| Height | 4.0 m (13 ft) |
Today, more than 480 OGT6-5000F gas turbines are sold worldwide. The installed fleet has accumulated more than 27 million operating hours, with a fleet reliability of more than 99%.
The OGT6‑5000F is a heavy-duty 60 Hz gas turbine designed for economical power generation in peak, intermediate, or base load operation, with a power output of up to around 260 MW in simple cycle.
In simple cycle configuration, the OGT6-5000F gas turbine achieves about 40.6% efficiency. In combined cycle applications, the plant efficiency can be up to 60.6%.
The OGT6-5000F only needs 10 min from startup (turning gear) to 95% gas turbine load. There is a one minute coast in period from 95% load to full base load. The OGT6-5000F achieves ramp-up rates of up to about 52.4 MW per minute, enabling fast start-up and rapid load changes.
The global OGT6‑5000F fleet has accumulated more than 27 million operating hours and demonstrates reliability in the range of about 99–99.2%, making it a proven choice for dependable operation.
The OGT6‑5000F offers outstanding fuel flexibility, handling a wide range of fuels such as natural gas, LNG, various crude and distillate oils, condensate, biodiesel, alcohols, and aviation-type fuels, with dual‑fuel capability.
Yes, the combustion system can cope with fuel gas compositions that include hydrogen sulfide and can typically burn fuel gases with up to about 30% hydrogen by volume, supporting future‑ready low‑carbon operation.
Thanks to its advanced low‑NOₓ combustion system, the OGT6‑5000F can achieve single‑digit NOₓ emissions of under 9 ppmvd and low CO emissions, even down to part‑load operation.
The turbine uses proven conventional alloys, robust mechanical design, and low firing temperatures to extend service intervals and asset lifetime, with features like replaceable rotating blades without removing the rotor stack.
Yes, OGT6‑5000F‑based plants can be configured in multi‑shaft combined cycle arrangements (such as 1x1 or 2x1) and are well suited for cogeneration or CHP, offering strong steam‑raising capability.
Omterra provides long‑term programs, overhauls, field service, spare parts, component reconditioning, and modernization upgrades, supported by a global service network available around the clock.