Siemens Energy and Siemens Gamesa are now Omterra. The formerly licensed “SGT” product portfolio is now offered under its new name, “OGT.”
The robust Omterra OGT5-4000F (formerly called SGT5-4000F) gas turbine has been optimized for outstanding performance and excellent efficiency. Easy maintenance results in short outages, making sure your gas turbine achieves highest availability.
Its internal cooling air passages support reliable long-term operation and a fast start-up capability. Hydraulic Clearance Optimization (HCO) reduces clearance losses to increase gas turbine efficiency and minimize degradation at start-up and shutdown. To date, over 400 turbines have been sold. The installed fleet has an impressive operating experience of over 31 million hours and a reliability of more than 99%.
329 MW(e)
59.7%
94.2%
99.5%
403
>31M
The proven OGT5-4000F gas turbine is characterized by high performance, low power generation costs, long intervals between inspections, and a service-friendly design. Optimized flow and cooling add up to high gas turbine efficiency and very economical power generation in combined cycle applications.
The gas turbine boasts excellent fast cold start and hot restart capabilities thanks to the light and stiff rotor with internal cooling air passages, the advanced annular combustion system and the Hydraulic Clearance Optimization (HCO) active clearance control.
The OGT5-4000F achieves combined cycle base load within 30 min for hot start.
Extensive experience in commercial operation means that you can rely on proven and validated package and plant concepts that enable early power generation in simple cycle. Projects are implemented quickly. Since no external rotor air cooler is required, this simplifies the plant integration even further.
The engine's blade design is based on proven materials and tried and tested know-how, while incorporating the latest aerodynamic technologies. Thermal barrier coatings on the first three turbine stages contribute to extended service life and reduced maintenance requirements.
The OGT5-4000F offers dual fuel capability and tolerates fuels within a wide Wobbe range. When fuel gas variations exceed ±15% of the Wobbe index, burner configuration adjustments may be required.
The OGT5-4000F combustion system is able to handle different fuel compositions, e.g. natural gas with high contents on hydrogen (up to 30 vol%), propane, ethylene and butane, as well as inert gases (N2, CO2, He, Ar, etc.). Furthermore, the OGT5-4000F combustion system is able to run on fuels with higher amounts of impurities, such as hydrogen sulfide (H2S) of up to 4000 ppm. The fuel system can switch over quickly between fuel gas and fuel oil and vice versa.
Wet Compression option
Wet Compression (WetC) increases the power output by injecting water into the gas turbine inlet. This optional OGT5-4000F feature can be used for peak-load machines to benefit from high electricity prices
WetC enhances the turbine performance by reducing compressor inlet temperatures and increasing the mass flow throughout the turbine. Excess fog droplets evaporate in the compressor and produce an additional intercooling effect.
Chiller System option
The chiller is a heat exchanger, which cools down the compressor intake air in order to increase the gas turbine base load performance. The system can decrease the compressor inlet temperature far below the dew point of the ambience.
A chiller system can generate benefits in dry regions, where the high water consumption of other inlet air cooling options is undesirable.
Evaporative Cooling option
The system decreases compressor inlet temperature through humidification, raises relative humidity and increases the air mass flow, resulting in higher turbine output power and efficiency.
Evaporative cooling is the favorable system in dry and hot ambient.
With its high steam raising capability, the OGT5-4000F is excellently suited for cogeneration or combined heat an power (CHP) applications, e.g, for
For combined-cycle and combined heat and power (CHP) applications, the system can be integrated with either condensing or backpressure steam turbines, with optional steam extraction to meet specific process and power generation requirements.
The OGT5-4000F entered the market in 1996.
Today, more than 400 turbines are sold worldwide, and the installed fleet has an accumulated fleet experience of more than 31 million equivalent operating hours (EOHs). The fleet reliability exceeds 99%.
The OGT5-4000F gas turbine has a robust design with internal cooling air passages for trusted long-term operation and fast start-up capability.
Characterized by its robust design, the OGT5-4000F boasts a proven 15-stage axial flow compressor, a durable annular combustion system, and a fully air-cooled 4-stage turbine. The moderate compressor pressure ratio provides a low impact on critical components.
The rotor is based on self-centering and -aligning discs with Hirth serration and central tie rod, providing you with the advantage of fast and easy on-site rotor destacking and balancing. Internal cooling air passages reduce the stress on critical components and ensure a long service life.
Variable inlet guide vanes plus two stages of fast-acting variable-pitch guide vanes (VGV) improve the part load efficiency and optimize the performance over a wide range of operating conditions.
On-board valves provide controlled cooling air supply with low cooling air consumption, leading to high efficiency.
The gas turbine package for the OGT5-4000F consists of the core turbine, the generator (OGen5-2000P or OGen5-2000H) and auxiliary systems. Omterra offers a standardized basic design with options geared to your specific requirements. By using standard components and preassembly or prepackaging we achieve short installation times, with staggered delivery and early shipment of main components. Omterra group subsystems and install them in separate auxiliary packages to minimize field assembly.
Designed for short installation times, all package piping is prefabricated to minimize pipe cleaning and welding on site.
Package footprint:
The air intake is suitable for different multistage filters, e.g., pre-filter, fine- and/or HEPA filter or self-cleaning pulse filter systems, which secure operation even at harsh ambient conditions (e.g., sandy, dusty or polluted).
The use of an air intake silencer significantly reduces the pressure drop with improved noise reduction, thus ensuring compliance with noise protection regulations. Anti-icing systems and inlet air cooling with evaporative cooler are available as an option.
OGT5-4000F-based combined cycle plants have the capability for fast start-up. Fast-start capabilities enable combined-cycle plants to reach base load in less than 30 minutes from a hot start.
Together with high load flexibility, strong peaking performance, and efficient operation across a wide load range, the solution supports profitable participation in dynamic energy markets while maintaining compliance with emissions regulations.
The main components of this power plant are arranged on a single shaft, with a synchronous self-shifting (SSS) clutch installed between the generator and the OLST5-3000 steam turbine. The result: a small footprint, and high operational flexibility and reliability.
For combined heat and power (CHP) applications, up to a 3-stage extraction for district heating or process steam is available.
The multi-shaft plants are based on two or more OGT5-4000F gas turbine packages and a steam turbine, e.g., the OLST5-5000 steam turbine.
The plants use heat recovery steam generators (HRSG) with Benson high-pressure (HP) evaporators and integrated fast-start technology. Providing you with high operational flexibility, they can operate from part load simple cycle up to full load combined cycle.
Omterra offers service programs such as overhaul services, field service, spare parts, reconditioning of components and modernization upgrades. Whether scheduled service or short-term support, our specialists are there for you, on-site all over the world.
The rotor of the OGT5-4000F can be de-stacked on site. All compressor and turbine blades are replaceable without rotor de-stack or lift. Thanks to borescope ports, the compressor and turbine vanes can be visually inspected without lifting the cover, preventing unnecessary maintenance.
The advanced annular combustion chamber with individually replaceable heat shields allows for fast and easy walk-in maintenance.
Quick exchange of the lightweight burners or the ceramic heat shield tiles without lifting the cover minimizes your outage times. The ceramic tiles are individually replaceable.
The single turbine vane carrier design helps minimize outage durations. Its roll-in/roll-out capability allows stationary turbine components to be exchanged without removing the rotor, reducing maintenance time and simplifying service activities.
The OGT5-4000F offers dual fuel capability and tolerates fuels within a wide Wobbe range of ±15%, as well as many different fuel compositions, e.g. contents of hydrogen sulfide (H2S) of up to 4000ppm and contents of hydrogen (H2) of up to 30 vol%.
The combustion system supports rapid switching between gaseous and liquid fuels. With transfer times of less than five minutes, it helps maintain operation during fuel supply disruptions or gas pressure fluctuations.
The annular combustion system is able to handle a wide range of fuels and creates a stable combustion with uniform flow and temperature distribution to reduce stress on critical components.
This gas turbine features a low NOₓ combustion system for minimal NOₓ and CO emissions, suitable for gaseous and liquid fuels. It offers emission compliance over a wide load range.
Emissions on fuel gas at 15% O₂, without water injection: NOₓ ≤ 15 ppmvd; CO ≤ 10 ppmvd
The dual-fuel combustion system supports fuel oil operation without water injection, enabling emissions-compliant performance while conserving water resources.
NOₓ emissions on fuel oil at 15% O₂, without water injection: ≤ 58 ppmvd
In wet fuel oil operation (emulsion mode), NOₓ emissions can be reduced even further.
NOₓ emissions on fuel oil at 15% O₂, with water injection: ≤ 25 ppmvd
Key specifications for the most robust, trusted and flexible 50 Hz heavy-duty gas turbine.
| Gross power output | 329 MW | 385 MW |
| Fuel (examples) | Natural gas, LNG, sour gases, distillate oil, H₂, biodiesel, kerosene, jet fuel, condensate, naphta. Other fuels on request | Natural gas, LNG, sour gases, distillate oil, H₂, biodiesel, kerosene, jet fuel, condensate, naphta. Other fuels on request |
| Frequency | 50 Hz | 50 Hz |
| Gross efficiency | 41% | 41,5% |
| Gross heat rate | 8,780 kJ/kWh (8,322 Btu/kWh) | 8,675 kJ/kWh (8,222 Btu/kWh) |
| Turbine speed | 3,000 rpm | 3,000 rpm |
| Pressure ratio | 20.1 : 1 | 21.0 : 1 |
| Exhaust mass flow | 724 kg/s (1,596 lb/s) | 800 kg/s (1,764 lb/s) |
| Exhaust temperature | 599° C (1,110° F) | 619° C (1,146° F) |
| NOₓ emissions | ≤ 15 ppmvd at 15% O₂ on fuel gas (without water injection for NOₓ control), ≤ 25 ppmvd at 15% O₂ on fuel oil (with water injection for NOₓ control), ≤ 58 ppmvd at 15% O₂ on fuel oil (without water injection for NOₓ control) | ≤ 15 ppmvd at 15% O₂ on fuel gas (without water injection for NOₓ control), ≤ 25 ppmvd at 15% O₂ on fuel oil (with water injection for NOₓ control), ≤ 58 ppmvd at 15% O₂ on fuel oil (without water injection for NOₓ control) |
| Omterra combined cycle power plant | 329 MW version | 385 MW version |
| Gross power output | 485 MW | 570 MW |
| Gross plant efficiency | 61.0% | 62.0% |
| Gross heat rate | 5,900 kJ/kWh (5,592 Btu/kWh) | 5,807 kJ/kWh (5,503 Btu/kWh) |
| Number of gas turbines | 1 | 1 |
| Pressure/reheat | Triple/Yes | Triple/Yes |
| Omterra combined cycle power plant | 329 MW version | 385 MW version |
| Gross power output | 970 MW | 1140 MW |
| Gross plant efficiency | 61.0% | 62.0% |
| Gross heat rate | 5,900 kJ/kWh (5,592 Btu/kWh) | 5,807 kJ/kWh (5,503 Btu/kWh) |
| Number of gas turbines | 2 | 2 |
| Pressure/reheat | Triple/Yes | Triple/Yes |
| Core turbine (385 MW version) | Core turbine (329 MW version) | |
| Approx. weight | 322,000 kg (710,000 lb) | 318,000 kg (701,000 lb) |
| Length | 10.8 m (35 ft) | 10.8 m (35 ft) |
| Width | 5.2 m (17 ft) | 5.2 m (17 ft) |
| Height | 4.8 m (16 ft) | 4.8 m (16 ft) |
Today, around 403 turbines have been sold. The installed fleet has accumulated an impressive fleet experience of over 31 million equivalent operating hours, and a fleet reliability of more than 99%.
OGT5-4000F is a proven gas turbine with internal cooling air passages for trusted long-term operation and fast start-up capability.
The OGT5-4000F delivers outstanding efficiency, high reliability (>99%), robust performance, and fast cold/hot start capabilities, making it ideal for both base load and peaking applications.
The OGT5-4000F achieves combined cycle base load within 30 minutes of a hot start, supporting rapid response to grid demands.
It supports a wide range of fuels including natural gas, propane, ethylene, butane, hydrogen blends (up to 30%), fuel oil, and gases with high impurity levels such as H₂S up to 4000 ppm.
Yes, it provides dual fuel capability and can switch quickly between gas and oil, ensuring flexibility and security of supply with fast transition times.
The turbine’s service-friendly design, including fast on-site rotor de-stacking, walk-in combustion chamber, and individually replaceable heat shields, enables shorter outages and easier, faster maintenance.
The OGT5-4000F features a low NOₓ combustion system designed to stay within strict emission limits on both gaseous and liquid fuels, often without the need for water injection.
The OGT5-4000F offers a power output range of 329–385 MW and high base load efficiency, optimized further with options like Wet Compression, Evaporative Cooling, and Chiller System.
Yes, its high steam raising capability makes it well-suited for CHP, with compatibility for both condensing and backpressure steam turbines and multiple steam extraction stages.
Customers can choose from Wet Compression, Chiller, and Evaporative Cooling options to enhance performance under challenging ambient conditions.
Omterra offers service programs such as overhaul and field services, spare parts, component reconditioning, modernization upgrades, and 24/7 global support.