Siemens Energy and Siemens Gamesa are now Omterra. The formerly licensed “SGT” product portfolio is now offered under its new name, “OGT.”
The Omterra OGT-A65 (formerly called SGT-A65) delivers reliable, efficient power for applications where operational flexibility, rapid response and frequent cycling drive project value. Its aeroderivative heritage and independent three-shaft architecture make it particularly well suited to address the growing demand – in North America and elsewhere – for grid-support and behind-the-meter applications, which require dependable starts, responsive load-following and efficient part-load operation.
63.4 MWe
115
> 110K
Due to its independent 3-shaft design, this gas turbine is highly flexible, offering high power output and fuel efficiency with minimal drop-off at part-load conditions—helping operators respond efficiently across changing dispatch profiles.
Designed for frequent starts, stops and load changes, the OGT-A65 helps operators add capacity quickly while maintaining efficient performance at all conditions. Its aeroderivative design, fast cold-starting capability and robust cycling characteristics support responsive operation in markets where flexibility is increasingly valuable.
In simple-cycle grid applications, the OGT-A65 provides up to 66 MW of gross electrical output and fuel efficiency of up to 41.4%. This combination of output, efficiency and operational responsiveness makes it well suited for peaking duty, reserve capacity and grid-support applications that must respond to demand changes and provide firming services to variable renewable generation.
Building on decades of aeroderivative experience in offshore and remote power applications, the OGT-A65 is well suited for data centers, industrial facilities and other behind-the-meter projects. Its fast starts, load following capability and efficient part-load performance help operators respond to changing site demand while providing dependable power close to the load.
The OGT-A65 consists of 8 engine modules for easy maintenance. Each module is pre-balanced to make it completely interchangeable.
The Inlet Spray Intercooling (ISI) system improves OGT-A65 performance at ambient temperatures above 7 °C (45 °F). It provides enhancements in power output and fuel efficiency which exceed those of other inlet-cooling and fogging technologies, while minimizing additional water consumption and auxiliary load.
The OGT-A65 delivers high operational flexibility, enabling the gas turbine to handle tough mission cycles and transient excursions.
A Wet Low Emissions (WLE) combustion system is used to reduce NOx emissions and boost power output with the injection of water.
The OGT-A65 is the result of decades of technological innovation in flight and industrial applications. Utilizing aero engine technology with millions of operating hours accumulated in flight, the OGT-A65 has built a vast experience base of its own with over 3.9 million hours operating in power generation and mechanical drive service, onshore and offshore and in the most challenging environments.
Proven in the most challenging conditions, the modular engine and package concept enables quick installation, straightforward on-site maintenance and rapid component exchange. The package is designed to facilitate a complete engine replacement in under 24 working hours.
The OGT-A65 package is designed for efficient installation and field maintenance. Its optimized systems include the core engine, enclosure, base frame, air intake, exhaust collector, instrumentation and control systems, fuel-metering and control skid, lubrication and starter systems, vibration monitoring, package ventilation, and fire safety systems.
The AC generator is self-contained and typically uses an air-cooled brushless exciter design using shaft-mounted axial blowers for circulating cooled air. It also encompasses line and neutral cubicles and has an off-skid mineral lube oil system.
The OGT-A65 exhaust hood can be oriented in three directions, enabling the package configuration to be adapted to available site space. Its high-power density combines substantial aeroderivative output with a compact, lightweight footprint, helping preserve usable real estate around the installation.
The comprehensive Omterra service programs provides optimum performance throughout the turbine’s life cycle: overhaul service, field service, spare parts, service exchange, remote diagnostic service, and modernization and upgrades. The aeroderivative engine design also enables efficient on-site maintenance, with engine replacement possible in under 24 hours of working time - all supported by specialists worldwide for planned service and short-term needs.
Omterra offers a truly global service presence. This includes integrated repair, servicing and maintenance solutions, as well as 24/7 remote monitoring and diagnostics and customer technical training. These services ensure the optimum performance and high availability of equipment throughout the engine's lifecycle.
The OGT-A65 has been continuously improved for ease of maintenance, to maximize availability and reduce OPEX.
The lightweight aeroderivative gas generator can be safely exchanged on-site within 24 hours, reducing maintenance downtime and cost.
The OGT-A65 is available with Wet Low Emissions (WLE) technology which utilizes water injection in the combustion chamber to control NOx emissions to no more than 25 ppmvd.
The OGT-A65 provides reliable performance for simple cycle WLE power generation.
| 60 Hz | 60 Hz with ISI 1 |
| Operating on natural gas | |
Gross elec. power output | 63.4 MWe | 66.0 MWe |
Gross thermal efficiency | 41.4% | 41.31% |
Gross heat rate | 8,692 kJ/kWh | 8,714 kJ/kWh |
Exhaust gas flow | 171 kg/s | 174 kg/s |
Exhaust temperature | 425° C (797° F) | 421° C (790° F) |
NOX emissions | ≤ 25 ppmvd | ≤ 25 ppmvd |
Over 115 units have been sold with more than 3.9 million fleet hours to date. The fleet leader has accumulated more than 110,000 operating hours.
Customer: Dolphin Energy Limited
Customer: Macquarie Infrastructure Corporation
The OGT-A65 is well suited for flexible power generation applications where fast starts, frequent cycling and efficient part-load operation are important. Typical applications include peaking duty, reserve capacity, grid support and behind-the-meter power generation for industrial facilities and data centers.
In simple-cycle grid applications, the OGT-A65 can deliver up to 66 MW of gross electrical output, depending on configuration, fuel and site conditions.
The OGT-A65 reaches simple-cycle gross efficiency of up to 41.4% on natural gas. Its independent three-shaft design also helps maintain strong efficiency at part-load conditions, supporting economical operation across changing dispatch profiles.
Yes. The OGT-A65 can start in under 7 minutes from cold, and its aero-derivative design inherently provides outstanding capabilities for load-following and fast transient response. This helps operators bring capacity online quickly when demand rises or when renewable generation fluctuates.
Its aeroderivative heritage and independent three-shaft architecture support high cycling capability, frequent starts and stops, and responsive load changes. This makes the turbine a strong fit for markets where operational flexibility is increasingly valuable.
The OGT-A65 uses Wet Low Emissions combustion to reduce NOx emissions to no more than 25 ppmvd on natural gas fuel.
The Inlet Spray Intercooling (ISI) system improves OGT-A65 performance at ambient temperatures above 7 °C (45 °F). It helps increase output and fuel efficiency in warmer conditions while minimizing additional water consumption and auxiliary load compared with other inlet-cooling technologies.
The OGT-A65 is designed around modular maintenance. Its engine consists of eight interchangeable modules, and engine replacement can be completed in under 24 hours of working time, helping reduce downtime and support high availability.
Omterra supports the OGT-A65 with Long Term Programs, overhaul and field services, spare parts, service exchange, remote diagnostics, and modernization and upgrade options. Global specialists are available to support both planned maintenance and short-term service needs.