OGT-750 lightweight industrial gas turbine
OGT-750 lightweight industrial gas turbine

OGT-750 lightweight industrial gas turbine

Siemens Energy and Siemens Gamesa are now Omterra. The formerly licensed “SGT” product portfolio is now offered under its new name, “OGT.”

With maximized uptime, top-class performance, and a low environmental footprint, the Omterra OGT-750 (formerly called SGT-750) offers you high lifetime profitability. It is a perfect choice for the oil and gas industry as well as for industrial power generation.

The OGT-750 is a lightweight industrial gas turbine designed and developed to incorporate the size and weight advantages of the aeroderivative gas turbine while maintaining the robustness, flexibility and longevity of the traditional heavy-duty industrial gas turbine.

OGT-750 industrial gas turbine

Engineered for maximum flexibility
Simple cycle power generation

41 MW(e)

Mechanical drive

42.2 MW

Average fleet availability

99.4%

Average fleet reliability

99.8%

Units sold

63

Total operating hours

>375K

The OGT-750 industrial gas turbine is an optimal solution for applications in the oil and gas industry and industrial power generation.

The OGT-750 combines class-leading efficiency and power output with Dry Low Emissions (DLE) technology. This combination contributes to low lifecycle operating costs and strong economic performance. Even at part load, the turbine maintains high efficiency while extending time between overhauls and delivering guaranteed NOₓ emissions as low as 9 ppm.

The combustor and burner designs deliver superior emission performance across a broad load range and are capable of achieving single-digit NOx emission levels.

The OGT-750 is the perfect option for power generation and offers a wide range of solutions, from stand-alone installations to complete power plants, industrial or oil and gas, onshore or offshore.
The fast start-up and cycling capabilities support intermediate to continuous operation. Lightweight and compact design allows for quick installation and easy maintenance.

Omterra offers a comprehensive range of extended-scope and turnkey solutions for mechanical drive applications. Backed by decades of experience, these solutions can be tailored to meet diverse application and project requirements.

  • Compressor applications (e.g., gas injection, gas processing, LNG, FLNG and pipelines)
  • Pump applications (water injection and fluid transmission projects)

The OGT-750 features a specifically service-friendly design:

  • Rollout for 24-hours gas generator swap
  • Easy on-site or off-site maintenance designed for only 14 maintenance days in 17 years
  • All components feature a modular design with best accessibility
  • Easy access for borescope inspection
  • IR cameras for early detection of possible deviations

The OGT-750 offers broad operational flexibility to address diverse market and application requirements. Its twin-shaft design and versatile driver configuration enable use in both power generation and mechanical drive applications, onshore and offshore.

For example:
Highest performance at extreme conditions, from arctic to desert conditions, fast start capability, quick load variations like load rejections or instant loading, wide fuel range, roll-and-pitch capability and free power turbine are just some of the operational benefits.

The OGT-750 is a modular, efficient engine suitable for onshore or offshore mechanical drive or heat and power. It features reliable performance and low emissions.

Ingenious design to the core

The OGT-750 gas turbine is designed to meet high demands for efficiency, reliability, uptime, and environmental compatibility. Its features include:

  • A 13-stage axial air compressor with an EB-welded rotor and two variable guide vanes for optimized performance even in extreme conditions.
  • A combustion system with 8 cans and 8 transition ducts, suitable for both liquid and gaseous fuels, designed for ease of maintenance and exchangeability without casing disassembly.
  • A free 2-stage power turbine with a nominal shaft speed of 6,100 rpm, offering flexibility for mechanical drive at speeds ranging from 50 to 105%.
  • Optimization for all ambient conditions, from cold to hot climates.
OGT-750 gas turbine

Proven design principles thanks to profound experiences

The OGT-750 combines proven technology and state-of-the-art materials.

OGT-750 gas turbine cut in half

Compact design meets all customer demands

The OGT-750 gas turbine is designed as a robust and compact indutrial gas turbine combined with aero engine performance.

OGT-750 package

The OGT-750 is delivered as a complete package, carefully designed to integrate supporting systems and customized solutions, ensuring a secured return on investment.

Its modular build-up allows for swift disassembly and parts replacement, with a 24-hour engine swap time to minimize downtime. All package options are available as single lift and share the same driver for mechanical drive and power generation, enhancing operational reliability.

OGT-750 power generation

OGT-750 for power generation

The OGT-750's fast start-up and cycling capabilities support both intermediate and continuous operation with improved turndown capability.

OGT-750 mechanical drive

OGT-750 for mechanical drive

With its twin-shaft configuration, the OGT-750 is driving compressors or pumps either onshore or offshore. Minimized starting power needed.

OGT-750 offshore

Offshore: roll and pitch

Small footprint due to compact design and highest availability – these are the best prerequisites for offshore applications as FLNG or FPSO.

The OGT-750 fires up

With maximized uptime, top-class performance, and a low environmental footprint, the OGT-750 industrial gas turbine offers a high lifetime profitability and is a perfect choice for the oil and gas industry as well as industrial power generation.
Fast start-up and cycling capabilities support both intermediate and continuous operation.
Omterra offers a wide range of solutions for power generation, from stand-alone installations to complete power plants for industrial and onshore or offshore power generation, and the oil and gas industry.

5 men with blue hats walk away from the SGT-750 gas turbine power plant

A scope to fit your needs for flexibility

Fast start-up and cycling capabilities support flexible operation across a wide range of duty cycles, from intermediate to continuous power generation.

Energy hub in Lubmin, Germany

Excellent combined cycle and combined heat and power efficiency

The OGT-750 is the perfect choice for combined cycle power plants for base load, standby power and peak lopping as well as cogeneration applications with heat load and district heating schemes.

14 maintenance days in 17 years

Omterra's service programs ensures low life cycle costs and optimal performance throughout the OGT-750's life cycle:

  • overhaul service
  • field service
  • spare parts
  • service exchange
  • remote diagnostic service
  • modernization and upgrades

Serviceability and maximizing uptime were top priorities during the OGT-750's development.

The OGT-750 offers the highest operational availability with 68,000 equivalent operating hours (EOHs) to first major overhaul and a service plan requiring only 14 maintenance days in 17 years. Planned service can be executed on-site or off-site without the need for special workshops, and the time between overhauls can be easily extended when operating on lower loads.

Additionally, all OGT-750 models are monitored with infrared cameras during scheduled inspections and engine delivery tests.

OGT-750 gas turbine package

Easy on-site maintenance

The enclosure is equipped with a traveling overhead crane allowing for easy offloading or loading on a truck.

OGT-750 core Engine in gas turbine package

Off-site maintenance with 24-hour core swap capability

For maximized availability, the gas generator can be swapped in less than 24 hours. It can be rolled out with standard maintenance tools.

Maximum fuel capability with minimum environmental impact

The fourth-generation DLE burner allows for excellent fuel flexibility. The OGT-750 operate on gases with high content of inert gases, hydrogen or heavy hydrocarbons as required, without any impact on maintenance or emission levels. The engine is capable to burn up to 40 vol% of hydrogen (H2).

The OGT-750 offers dual-fuel capability for all applications. It is designed to meet the individual operating criteria, including a reliable start, and changeover between fuels. The automatic changeover from gaseous to liquid fuel, and back again, can be executed at any load.

ogt-750 gas turbine can combustors with DLE burners

Can combustors with DLE burners

Dry low emission technology allows for maximum fuel flexibility.

sgt-750 can combustor detail

Dual-fuel capability

The OGT-750 has dual-fuel and on-load fuel changeover capabilities.

Single digit NOx over a wide load range

The OGT-750 is equipped with a fourth-generation Dry Low Emissions (DLE) system for clean combustion over a wide load range, ensuring a small environmental footprint. The gas turbine is designed to meet both global and regional regulatory requirements.
The design gives a world-class emission performance over a wide load range with single-digit NOₓ capability.

dry low emissions burner ogt-750

DLE burners for single-digit emissions

Emission requirements are meeting operational criteria including flexible fuel operation and reliable starting.

inside of can combustor ogt-750

State-of-the-art combustion technology

Can combustors with double skin-cooled design are suitable for both liquid and gaseous fuels.

The OGT-750 is ideal for industrial power, oil and gas, mechanical drive, combined cycle, and combined heat and power plants.

Performance data for simple cycle power generation

The OGT-750 can be configured to any power rating from 38.9 to 41.1 MW.

 42 MW version41 MW version
Gross power output41.0 MW(e)38.9 MW(e)
Fuel¹Natural gas, liquid fuel, dual fuelNatural gas, liquid fuel, dual fuel
Frequency50/60 Hz50/60 Hz
Gross efficiency40.5%40.2%
Gross heat rate8,898 kJ/kWh (8,434 Btu/kWh)8,946 kJ/kWh (8479 Btu/kWh)
Turbine speed 6,100 rpm 6,100 rpm
Pressure ratio25.6 : 124.9 : 1
Exhaust mass flow118.1 kg/s(260,4 lb/s)116 kg/s(255,7 lb/s)
Exhaust temperature 458 °C (874 °F)467 °C (855 °F)
NOₓ emissions²< 9 ppmvd< 7 ppmvd
All performance values are based on standard design, ISO ambient conditions and natural gas fuel. No intake or exhaust loss. | ¹Natural gas, other gases within specification, liquid fuel (Diesel No. 2) and dual fuel (gas and liquid) | ²NOₓ emissions at 15% O₂ on fuel gas (with DLE)

OCC-750: Performance data for combined cycle power plant

 OCC-750 1x1OCC-750 2x1
Gross power output53.9 MW(e)108.1 MW(e)
Gross plant efficiency54.1%54.3%
Gross heat rate6,656 kJ/kWh (6,309 Btu/kWh)6,633 kJ/kWh (6,287 Btu/kWh)
Number of gas turbines12
All combined cycle performance is based on 2 pressure, no reheat.

Performance data for mechanical drive

The OGT-750 can be configured to any power rating from 40 to 42.2 MW.

Gross power output42.2 MW41 MW
Fuel¹Natural gas, liquid fuel, dual fuelNatural gas, liquid fuel, dual fuel
Gross efficiency41.7%41.5%
Gross heat rate8,642 kJ/kWh (6,108 Btu/kWh)8,681 kJ/kWh (6,136 Btu/kWh)
Drive shaft speed 3050-6405 rpm 3050-6405 rpm
Pressure ratio25.6 : 124.9 : 1
Exhaust mass flow118.1 kg/s (260,4 lb/s)116 kg/s (255,7 lb/s)
Exhaust temperature 468 °C (874 °F)457 °C (855 °F)
NOₓ emissions²< 9 ppmvd< 7 ppmvd
Maintenance interval (TBO)30 kOH / 60 kOH36 kOH / 68 kOH
All performance values are based on standard design, ISO ambient conditions and natural gas fuel. No intake or exhaust loss. | ¹Natural gas, other gases within specification, liquid fuel (Diesel No. 2) and dual fuel (gas and liquid) | ²NOₓ emissions at 15% O₂ on fuel gas (with DLE)

Physical dimensions and weight

 Power generation packageMechanical drive packageOffshore Power generation package
Approx. weight175,000 kg (385,809 lb)76,000 kg (167,551 lb)261,000 kg (575,500 lb)
Length20.3 m (66.6 ft)12.8 m (40.4 ft)20.0 m (65.5 ft)
Width4.8 m (15.8 ft)4.3 m (14.1 ft)5.7 m (18.7 ft)
Height4.1 m (13.5 ft)4.1 m (13.5 ft)6.4 m (21.0 ft)
The above dimensions exclude inlet filter housing and exhaust stack. For power generation, an AC generator is included. For mechanical drive, driven equipment is excluded.

Articles and Papers

icon

Get in touch with us

For information and questions, our support team is available 24/7 to assist you in English, Spanish, and German.
Country/region
Job role
Is your inquiry related to installed equipment?
Industry (Select up to three)
Marketing consent