OGT-700 gas turbine: high fuel adaptability and minimal emissions
OGT-700 gas turbine: high fuel adaptability and minimal emissions

OGT-700 gas turbine: high fuel adaptability and minimal emissions

Siemens Energy and Siemens Gamesa are now Omterra. The formerly licensed “SGT” product portfolio is now offered under its new name, “OGT.”

Derived from the OGT-600, the Omterra OGT-700 (formerly called SGT-700) is designed to offer higher output and efficiency, as well as lower emissions and a wide range of fuel capabilities.

OGT-700 is ideal for power generation and mechanical drive applications. Thanks to its high exhaust heat, it is also excellent for cogeneration and combined cycle applications. To date, more than 165 units have been sold, achieving over 6.2 million operating hours and demonstrating a class-leading reliability rate of 99.5%.

OGT-700 industrial gas turbine key facts

Engineered for maximum flexibility
Simple cycle power generation

33 MW(e)

Mechanical drive

33.9 MW

Average fleet availability

98.3%

Average fleet reliability

99.8%

Units sold

165

Total operating hours

>6.2M

The OGT-700 gas turbine stands out for its advanced features and impressive performance. Discover key highlights including exceptional fuel flexibility, cutting-edge emissions control, and maximized operational reliability.

The OGT-700 offers best-in-class fuel flexibility that allows for high content of inert gases, hydrogen and heavy hydrocarbons:

  • Ethane 100%
  • Propane 100%
  • Butanes and heavy alkanes 15%
  • Hydrogen up to 55%
  • Nitrogen 40%
  • H₂S 3%

The OGT-700 features a third-generation dual-fuel Dry Low Emissions (DLE) combustion system:

  • NOₓ emissions level < 15 vppm
  • CO emissions level  < 20 vppm
  • Turn down 50% load
  • Same DLE system for dual and liquid operation
  • NOₓ emissions on liquid fuels < 58 ppmvd
  • CO emissions on liquid fuels < 25 ppmvd
  • Turn down 50% on liquid fuels
  • Dual-fuel DLE capability with fuel changeover capability (gas to liquid fuel and liquid fuel to gas) on load

The OGT-700 features a reliable, robust and easily maintainable design for maximized uptime.

  • Reliability > 99%
  • On-site or off-site maintenance
  • 24-hour swap capability
  • 17 maintenance days in 15 years
  • 30,000 equivalent operating hours (EOHs) between hot section inspections
  • Part load operation increases the time between overhauls

Thanks to a long lifetime with maximized uptime, low lifecycle cost and easy servicability, the OGT-700 offers a high lifetime profitability. The robust industrial design offers a low degradation over time.

The OGT-700 offers superior availability within its class, attributable to its durable and extensively tested design.

Ingenious design to the core

The OGT-700 provides the best availability of its class, thanks to a robust and well-proven design. The compact twin-shaft engine is easy to maintain and allows for flexible operation with excellent efficiency at part load conditions.

Using the same design for power generation and mechanical drive increases the operational reliability.

OGT-700 gas turbine cut open

Reliable and easy to maintain

The OGT-700 employs an 11-stage axial-flow transonic compressor incorporating the latest aerodynamics, with variable guide vanes for robust operability and optimized performance over a wide range of operating conditions.

OGT-700 gas turbine

Two-stage free power turbine

The 2-stage uncooled free power turbine offers a nominal shaft speed of up to 6,500 rpm. For mechanical drive, it may operate at 50 to 105% of the nominal speed. The  power turbine can be matched for optimal performance at different ambient conditions.

Packages for power generation and mechanical drive

The OGT-700 package offers a small footprint and excellent serviceability. It features a modular and flexible design with single-lift capability.

The driver for both the power generation and the mechanical drive package is the same.

A gas turbine package includes:

Gas turbine, enclosure, base frame, air intake, exhaust, lubricating systems, starter system, vibration monitoring system, firefighting system, package ventilation system, instrumentation, gas detection, fuel systems, gearbox (if needed).

OGT-700 power generation package

Power generation package

The OGT-700 is ideal for simple cycle, combined cycle, cogeneration, and other heating applications thanks to its high exhaust temperature and the ability to handle sudden load changes.

  • Low space requirements
  • Modular design for high versatility
  • Optimized for easy transportation
OGT-700 mechanical drive package

Mechanical drive package

Extreme desert and arctic climates, or harsh industrial environments are not expected to impair the OGT-700 mechanical drive package’s long service life.

  • Variable power turbine speed: 50 to 105%
  • High load on low-power turbine speed
  • Extended lifetime on part-load operation
  • Low part-load emissions

OGT-700-based power plants

For combined cycle and cogeneration (combined heat and power – CHP), Omterra offers a broad range of power plant configurations and scopes based on the OGT-700 gas turbine. For combined cycle, 1x1 or 2x1 configurations are part of the standardized portfolio.

OGT-700 based power plants

Excellent CC and CHP efficiency

High combined cycle performance: In a 2x1 combined cycle configuration, the power output is 91.6 MW(e) at a net plant efficiency of 53.1%.

OGT-700 gas turbine maintenance

Easy on-/off-site maintenance

The OGT-700 is designed for maximized serviceability.

  • On-site maintenance or a gas generator removal for off-site maintenance
  • Gas generator swap within 24 hours
remote diagnostic static animation

Remote diagnostic service

  • The remote diagnostic service helps detect faults early and prevent outages.
  • It includes online monitoring, expert analysis of performance data, and fleet data comparisons.
OGT-700 gas turbine blades

Designed for easy serviceability

  • Burners are accessible from the outside for easy replacement.
  • The compressor casing is horizontally split, and the turbine casing is vertically split between gas generator and power turbine.
  • Multipe boroscope holes allow for internal visual inspection of the compressor.

Excellent fuel flexibility

The OGT-700 offers best-in-class fuel flexibility that allows for high content of inert gases, hydrogen and heavy hydrocarbons:

  • Ethane 100%
  • Propane 100%
  • Butanes and heavy alkanes 15%
  • Hydrogen up to 55%
  • Nitrogen 40%
  • H₂S 3%

The OGT-700 requires low gas supply pressure at site: 28 bar(a) / 406 psi(a).
Fuel changeover (gas to liquid fuel and liquid fuel to gas) on load.

Low emission capability

The combustor and burner design give world-class emission performance over a wide load range and are capable of low NOₓ emission levels.
Low emission levels are also received on liquid fuel without need of water injection.

Emissions for 100 – 50% load, NOₓ at 15% O₂:

  • Natural gas: ≤ 15 – 25 ppmv
  • Diesel No. 2: ≤ 42 – 58 ppmv

Emissions for 100 - 50% load, CO at 15% O₂:

  • Natural gas: ≤ 10 – 25 ppmv
  • Diesel No. 2: ≤ 25 ppmv

(Emissions depend upon site conditions, required load range and other project-specific data.) 

The OGT-700 is ideal for industrial power, oil and gas, mechanical drive, combined cycle, and combined heat and power plants.

Performance data for simple cycle power generation

 35 MW rating33 MW rating
Gross power output35.2 MW(e)32.6 MW(e)
Fuel¹Natural gas, liquid fuel, dual fuelNatural gas, liquid fuel, dual fuel
Frequency50/60 Hz50/60 Hz
Gross efficiency38.0%36.8%
Gross heat rate9,466 kJ/kWh (8,972 Btu/kWh)9,778 kJ/kWh (9,268 Btu/kWh)
Turbine speed6,500 rpm6,500 rpm
Pressure ratio20.4 : 119.7 : 1
Exhaust mass flow98.7 kg/s (217.6 lb/s)96.4 kg/s (212.6 lb/s)
Exhaust temperature531 °C (988 °F)530 °C (986 °F)
NOₓ emissions²≤ 15 ppmvd≤ 15 ppmvd
All performance values are based on standard design, ISO ambient conditions and natural gas fuel. No intake or exhaust loss. ¹ Natural gas, other gases within specification, liquid fuel (Diesel No. 2) and dual fuel (gas and liquid) ²NOₓ emissions at 15% O₂ on fuel gas (with DLE)

Performance data combined cycle power generation

OCC-700: Performance data for 1x1 combined cycle power plant
 35 MW rating33 MW rating
Gross power output49.8 MW46.8 MW
Gross plant efficiency54.5%53.6%
Gross heat rate6,609 kJ/kWh (6,264 Btu/kWh)6,723 kJ/kWh (6,372 Btu/kWh)
Number of gas turbines11
OCC-700: Performance data for 2x1 combined cycle power plant
 35 MW rating33 MW rating
Gross power output100 MW92.6 MW
Gross plant efficiency54.7%53.7%
Gross heat rate6,576 kJ/kWh (6,233 Btu/kWh))6,703 kJ/kWh (6,353 Btu/kWh)
Number of gas turbines22
All combined cycle performance is based on 2 pressure, no reheat.

Performance data for mechanical drive

 35 MW rating33 MW rating
Gross power output36.2 MW33.5 MW
Fuel¹Natural gas, liquid fuel, dual fuelNatural gas, liquid fuel, dual fuel
Gross efficiency39.0%37.8%
Gross heat rate9,230 kJ/kWh (6,524 Btu/kWh)9,527 kJ/kWh (6,734 Btu/kWh)
Drive shaft speed3,250 – 6,500 – 6,825 rpm3,250 – 6,500 – 6,825 rpm
Pressure ratio20.4 : 119.7 : 1
Exhaust mass flow98.7 kg/s (217.6 lb/s)96.4 kg/s (212.6 lb/s)
Exhaust temperature531 °C (988 °F )530 °C (986 °F )
NOₓ emissions²≤ 15 ppmvd≤ 15 ppmvd
All performance values are based on standard design, ISO ambient conditions and natural gas fuel. No intake or exhaust loss. ¹Natural gas, other gases within specification, liquid fuel (Diesel No. 2) and dual fuel (gas and liquid) ²NOₓ emissions at 15% O₂ on fuel gas (with DLE)

Physical dimensions and weight

 Power generation packageMechanical drive package
Approx. Weight 35 MW rating:169,755 kg (374,245 lb)63,050 kg (139,000 lb)
Length18.8 m (61.7 ft)11.7 m (38.4 ft)
Width4.6 m (15.0 ft)4.0 m (13.1 ft)
Height4.0 m (13.1 ft)4.0 m (13.1 ft)
 Power generation packageMechanical drive package
Approx. Weight 33 MW rating:163,193 kg (359,779 lb)63,050 kg (139,000 lb)
Length18.8 m (61.7 ft)11.7 m (38.4 ft)
Width4.6 m (15.0 ft)4.0 m (13.1 ft)
Height4.0 m (13.1 ft)4.0 m (13.1 ft)
Dimensions exclude inlet filter housing and exhaust stack. For power generation, the AC generator is included. For mechanical drive, the driven equipment is excluded.

More than 165 units have been sold with over 6.2 million equivalent operating hours. The fleet-leading gas turbine has over 162,000 equivalent operating hours.

Do you have a question regarding Omterra products, solutions and services?

icon

Get in touch with us

For information and questions, our support team is available 24/7 to assist you in English, Spanish, and German.
Country/region
Job role
Is your inquiry related to installed equipment?
Industry (Select up to three)
Marketing consent